ROTATIONAL CORONARY ATHERECTOMY WITH ADJUNCTIVE BALLOON ANGIOPLASTY FOR THE TREATMENT OF OSTIAL LESIONS

被引:29
|
作者
ZIMARINO, M
CORCOS, T
FAVEREAU, X
COMMEAU, P
TAMBURINO, C
SPAULDING, C
GUERIN, Y
机构
[1] CTR MEDICOCHIRURG PARLY GRAND CHESNAY, F-78150 LE CHESNAY, FRANCE
[2] CLIN ST MARTIN, CAEN, FRANCE
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1994年 / 33卷 / 01期
关键词
ROTATIONAL CORONARY ATHERECTOMY; PTCA; OSTIAL LESIONS;
D O I
10.1002/ccd.1810330106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conventional balloon angioplasty (PTCA) of ostial lesions (OL) is associated with suboptimal results and a higher complication rate. Partial plaque ablation with rotational atherectomy (RA) before PTCA might improve results. This approach was used in 63 patients (pts) (mean age 64+/-10 yrs; 44 men, 19 women) with 69 OL. There were 15 aorto-OL and 54 branch-OL. Calcification was more frequent in aorto-OL than in branch-OL (67% vs. 35%, P<0.05). Mean burr size was 1.8+/-0.3 mm. Burr-artery ratio was 0.74+/-0.10. Adjunctive PTCA was systematically performed. Procedural success was achieved in 58 pts (92%): 14 aorto-OL (93%) and 50 branch-OL (93%) were successfully treated; major complications occurred in 1 (7%) aorto-OL and 1 (2%) branch-OL. Uncomplicated failure occurred in three cases. Minimal lumen diameter (MLD) increased from 0.69+/-0.31 mm before RA to 1.43+/-0.28 mm after PA (P<0.001) and 2.16+/-0.29 mm after PTCA (P<0.001). Diameter stenosis (DS) decreased from 75+/-13% before RA to 32+/-12% after RA (P<0.001) and 14+/-10% after PTCA (P<0.001). All successfully treated pts underwent repeat angiography 24 h later and exercise testing or repeat cardiac catheterization >6 mo later. At 24 h repeat angiography, os was 17+/-15% (P=NS vs. after PTCA); no lesion had a DS greater than or equal to 50%. Follow-up coronary angiography was performed in 30 pts (52%) who had abnormal stress testing: 13 pts (43%) showed angiographic restenosis in at least one successfully treated OL. In conclusion, RA with adjunctive PTCA is a safe and effective treatment of OL. It is associated with higher success and lower major complications rates when compared with conventional PTCA. Restenosis remains a major limitation of all percutaneous approaches. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [31] Treatment of in-stent coronary restenosis with excimer laser angioplasty
    Liu, ML
    Chow, WH
    Kwok, OH
    Jim, MH
    Yip, A
    Fan, K
    Chan, E
    CHINESE MEDICAL JOURNAL, 2000, 113 (01) : 14 - 17
  • [32] Early and midterm outcomes of bioresorbable vascular scaffolds for ostial coronary lesions: insights from the GHOST-EU registry
    Gori, Tommaso
    Wiebe, Jens
    Capodanno, Davide
    Latib, Azeem
    Lesiak, Maciej
    Pyxaras, Stylianos A.
    Mehilli, Julinda
    Caramanno, Giuseppe
    Di Mario, Carlo
    Brugaletta, Salvatore
    Weber, Julia
    Capranzano, Piera
    Sabate, Manel
    Mattesini, Alessio
    Geraci, Salvatore
    Naber, Christoph K.
    Araszkiewicz, Aleksander
    Colombo, Antonio
    Tamburino, Corrado
    Nef, Holger
    Muenzel, Thomas
    EUROINTERVENTION, 2016, 12 (05) : E550 - E556
  • [33] Assessment of intravascular ultrasound-bearing balloon catheter-guided percutaneous transluminal coronary angioplasty and stenting
    Kawata, M
    Okada, T
    Igarashi, N
    Okajima, K
    Domoto, Y
    Mizutani, T
    HEART AND VESSELS, 1997, : 185 - 187
  • [34] Differences in the morphology of unstable and stable coronary lesions and their impact on the mechanisms of angioplasty - An in vivo study with intravascular ultrasound
    Kearney, P
    Erbel, R
    Rupprecht, HJ
    Ge, J
    Koch, L
    Voigtlander, T
    Stahr, P
    Gorge, G
    Meyer, J
    EUROPEAN HEART JOURNAL, 1996, 17 (05) : 721 - 730
  • [35] CORONARY ANGIOPLASTY USING AN OVER-THE-WIRE BALLOON CATHETER THROUGH A NEW 6-FRENCH GUIDING CATHETER
    UENO, K
    KOTOO, Y
    ARAI, M
    MATSUBARA, T
    WATANABE, S
    ITO, H
    HIRAKAWA, S
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 26 (01): : 61 - 68
  • [36] Validation of an automated technique for determining the mechanical characteristics of coronary arteries during balloon angioplasty: laboratory assessment with necropsy segments
    Murray, A
    Allen, V
    Bennett, MK
    HEART, 1998, 79 (06) : 608 - 612
  • [37] Fracture of cutting balloon microsurgical blade inside coronary artery during angioplasty of tough restenotic lesion: A case report
    Haridas, KK
    Vijayakumar, M
    Viveka, K
    Rajesh, T
    Mahesh, NK
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) : 199 - 201
  • [38] Lipoprotein (a) and anticardiolipin antibodies are risk factors for clinically relevant restenosis after elective balloon percutaneous transluminal coronary angioplasty
    Chiarugi, L
    Prisco, D
    Antonucci, E
    Capanni, M
    Fedi, S
    Liotta, AA
    Margheri, M
    Simonetti, I
    Gensini, FG
    Abbate, R
    ATHEROSCLEROSIS, 2001, 154 (01) : 129 - 135
  • [39] PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY UTILIZING PROLONGED BALLOON INFLATIONS - INITIAL RESULTS AND 6-MONTH FOLLOW-UP
    STAUDACHER, RA
    HESS, KR
    HARRIS, SL
    ABUKHALIL, J
    HEIBIG, J
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 23 (04): : 239 - 244
  • [40] Five-year angiographic outcome in patients without restenosis following coronary balloon angioplasty: A comparison between non diabetic and diabetic
    Takenaka, S
    Nakamura, N
    Shiode, N
    Shirota, K
    Suyama, H
    Goto, Y
    Hirao, H
    Nakazawa, Y
    Inoue, K
    Nagamatsu, T
    JAPANESE HEART JOURNAL, 2003, 44 (01): : 31 - 39