THE HERBERT BONE SCREW - A 10 YEAR PERSPECTIVE

被引:56
作者
HERBERT, TJ [1 ]
FISHER, WE [1 ]
LEICESTER, AW [1 ]
机构
[1] SYDNEY HOSP,HAND UNIT,SYDNEY,NSW 2000,AUSTRALIA
关键词
D O I
10.1016/S0266-7681(05)80265-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
It is now over ten years since the Herbert bone screw was first released in Australia. In 1984, Herbert and Fisher first published their experience with the use of this new bone screw in the management of scaphoid fractures. Since that time, there has been a growing interest in the technique and over 60 articles have appeared in the English literature. The purpose of this paper is to review and comment on the relevant publications as they relate to the biomechanical properties of the screw, to its use in the management of scaphoid fractures and to other applications in surgery of the hand.
引用
收藏
页码:415 / 419
页数:5
相关论文
共 35 条
[1]  
Adams B.D., Blair W.F., Reagan D.S., Grunberg A.B., Technical factors related to Herbert screw fixation, Journal of Hand Surgery, 13A, 6, pp. 893-899, (1988)
[2]  
Ayres J.R., Goldstrohm G.L., Miller G.J., Dell P.C., Proximal interphalangeal joint arthrodesis with the Herbert screw, Journal of Hand Surgery, 13A, 4, pp. 600-603, (1988)
[3]  
Botte M.J., Gelberman R.H., Modified technique for Herbert screw insertion in fractures of the scaphoid, Journal of Hand Surgery, 12A, 1, pp. 149-150, (1987)
[4]  
Bunker T.D., Macnamee P.B., Scott T.D., The Herbert screw for scaphoid fractures. A multicentre study, Journal of Bone and Joint Surgery, 69B, 4, pp. 631-634, (1987)
[5]  
Carter P.R., Malinin T.I., Abbey P.A., Sommerkamp T.G., The scaphoid allograft: A new operation for treatment of the very proximal scaphoid nonunion or for the necrotic, fragmented scaphoid proximal pole, Journal of Hand Surgery, 14A, 1, pp. 1-11, (1989)
[6]  
Chun S., Wicks B.P., Meyerdierks E., Werner F., Mosher J.F., Two modifications for insertion of the Herbert screw in the fractured scaphoid, Journal of Hand Surgery, 15A, 4, pp. 669-671, (1990)
[7]  
Cooney W.P., Linscheid R.L., Dobyns J.H., Wood M.B., Scaphoid nonunion: role of anterior interpositional bone grafts, Journal of Hand Surgery, 13A, 5, pp. 635-649, (1988)
[8]  
Demaagd R.L., Engber W.D., Retrograde Herbert screw fixation for treatment of proximal pole scaphoid nonunions, Journal of Hand Surgery, 14A, 6, pp. 996-1003, (1989)
[9]  
Faithfull D.K., Herbert T.J., Small joint fusions of the hand using the Herbert bone screw, Journal of Hand Surgery, 9B, 2, pp. 167-168, (1984)
[10]  
Fernandez D.L., A technique for anterior wedge-shaped grafts for scaphoid nonunions with carpal instability, Journal of Hand Surgery, 9A, 5, pp. 733-737, (1984)