Indoor air quality levels in a University Hospital in the Eastern Province of Saudi Arabia

被引:44
作者
El-Sharkawy, Mahmoud F. [1 ]
Noweir, Mohamed E. H. [1 ]
机构
[1] Univ Dammam, Coll Appl Med Sci, Dept Environm Hlth, POB 2435, Dammam 31451, Saudi Arabia
关键词
Air pollutants; air quality guidelines; biological pollutants; hospital environment; indoor air quality; outdoor air pollution; traffic activity; university campuses;
D O I
10.4103/2230-8229.128778
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Aim of the Study: The complex hospital environment requires special attention to ensure a healthy indoor air quality (IAQ) to protect patients and healthcare workers against hospital-acquired infections and occupational diseases. Poor hospital IAQ may cause outbreaks of building-related illness such as headaches, fatigue, eye, and skin irritations, and other symptoms. The general objective for this study was to assess IAQ inside a large University hospital at Al-Khobar City in the Eastern Province of Saudi Arabia. Materials and Methods: Different locations representing areas where most activities and tasks are performed were selected as sampling points for air pollutants in the selected hospital. In addition, several factors were studied to determine those that were most likely to affect the IAQ levels. The temperature and relative percent humidity of different air pollutants were measured simultaneously at each location. Results: The outdoor levels of all air pollutant levels, except volatile organic compounds (VOCs), were higher than the indoor levels which meant that the IAQ inside healthcare facilities (HCFs) were greatly affected by outdoor sources, particularly traffic. The highest levels of total suspended particulates (TSPs) and those less than 10 microns (PM 10) inside the selected hospital were found at locations that are characterized with m4ore human activity. Conclusions: Levels of particulate matter (both PM 10 and TSP) were higher than the Air Quality Guidelines (AQGs). The highest concentrations of the fungal species recorded were Cladosporium and Penicillium. Education of occupants of HCF on IAQ is critical. They must be informed about the sources and effects of contaminants and the proper operation of the ventilation system.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 46 条
[1]  
[Anonymous], 2002, WORLD HLTH REPORT 20
[2]  
ASHRAE, 2001, 622001 ASHRAE ANSIAS
[3]  
ASHRAE, 1999, ASHRAE HDB
[4]   A regional comparison of mold spore concentrations outdoors and inside "clean" and "mold contaminated" southern California buildings [J].
Baxter, DM ;
Perkins, JL ;
McGhee, CR ;
Seltzer, JM .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2005, 2 (01) :8-18
[5]  
Berne RM, 2010, BERNE LEVY PHYSL
[6]   Relationship between outdoor and indoor air quality in eight French schools [J].
Blondeau, P ;
Iordache, V ;
Poupard, O ;
Genin, D ;
Allard, F .
INDOOR AIR, 2005, 15 (01) :2-12
[7]   Air pollution and cardiovascular disease - A statement for healthcare professionals from the expert panel on population and prevention science of the American Heart Association [J].
Brook, RD ;
Franklin, B ;
Cascio, W ;
Hong, YL ;
Howard, G ;
Lipsett, M ;
Luepker, R ;
Mittleman, M ;
Samet, J ;
Smith, SC ;
Tager, I .
CIRCULATION, 2004, 109 (21) :2655-2671
[8]   Epidemiological evidence of effects of coarse airborne particles on health [J].
Brunekreef, B ;
Forsberg, B .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) :309-318
[9]  
Burr M L, 2001, Rev Environ Health, V16, P97
[10]   Microanalysis methods for characterization of personal aerosol exposures [J].
Carlton, AG ;
Turpin, BJ ;
Johnson, W ;
Buckley, BT ;
Simcik, M ;
Eisenreich, SJ ;
Porcja, RJ .
AEROSOL SCIENCE AND TECHNOLOGY, 1999, 31 (01) :66-80