IMPROVEMENT OF TRANSMISSION-LINE GROUND CIRCUIT CURRENT-CARRYING LIMIT AFTER SYSTEM INTERCONNECTIONS

被引:3
|
作者
SOBRAL, ST
NOVAES, EO
COELHO, ASR
机构
关键词
D O I
10.1109/61.248317
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When one or more transmission lines are added to an existing transmission system, the intensity Of the fault currents flowing along the ground wires near the substations may exceed the ground wire thermal limit. In such cases, it is generally preferred to improve the existing ground wire conductivity by replacing, say a steel ground wire with an ACSR ground wire along the first spans near the substation. Generally, this procedure requires that the transmission line be de-energized, what may sometimes be considered unacceptable. This paper deals with optional procedures which can be implemented in the first line kilometers near the substations keeping the existing lines energized. Such procedures include sectionalizing of ground wires, use of continuous counterpoise and use of additional overhead ground wires installed below the conductors. This paper introduces also a technique called by us ''tower foot resistance adjustment'', which complements the corrective effects of the mentioned procedures. The extension of the ''Decoupled Method'' [5,6,4,3,2,7,1] to represent the above suggested procedures is detailed in this paper which also includes a practical example occurred when the 220 kv Paraguayan system was connected to the Itaipu Collector System. The existing 220 kV lines have steel ground wires and leave the Acaray 250 MW Hydroelectric Power Plant. These transmission lines have been designed some 20 years ago to feed the main 220 kV Paraguayan network, i. e., a long time before the itaipu Power Plant location studies had been started. The connection between the Itaipu System and the Paraguayan System is presently done by two 5 km long 220 kV transmission lines, (L-1) and (L-2) having ACSR ground wires, as shown in Figure 1.
引用
收藏
页码:2023 / 2030
页数:8
相关论文
共 19 条
  • [11] A Stable Energy Acquisition System Based on Magnetic Circuit Coupled Current Transformer for Transmission Line
    Zhang, Pengyu
    Meng, Runquan
    Ren, Chunguang
    Zhang, Ying
    2019 3RD INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2019), 2019, 267
  • [12] TRANSMISSION-LINE EQUIVALENT-CIRCUIT MODEL OF MINORITY-CARRIER TRANSIENT CURRENT IN QUASI-NEUTRAL SILICON LAYERS INCLUDING INDUCTIVE EFFECTS
    KARAMARKOVIC, JP
    JANKOVIC, ND
    GLOZIC, DB
    INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 1995, 8 (05) : 341 - 356
  • [13] Experimental study on limiting operation of superconducting fault current limiter in double circuit transmission line model system
    Hatta, H
    Muroya, S
    Nitta, T
    Shirai, Y
    Taguchi, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) : 812 - 815
  • [14] Short-circuit Fault Current Analysis of AC Transmission Line of MMC-MTDC System for Wind Power Intergration
    Qin J.
    Jia K.
    Yang B.
    Chen J.
    Bi T.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (14): : 47 - 55
  • [15] Circuit simulation of current loss in magnetically insulated transmission line system in 15-MA Z-pinch driver
    Gong Zhen-Zhou
    Wei Hao
    Fan Si-Yuan
    Sun Feng-Ju
    Wu Han-Yu
    Qiu Ai-Ci
    ACTA PHYSICA SINICA, 2022, 71 (10)
  • [16] Field and circuit formulation of the fundamental problem about transmission of electromagnetic energy in a "metallic wire conducting ground" system with alternative electric current
    Baranov, M., I
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2008, (02) : 59 - +
  • [17] Simulation and analysis of induced voltage and current on overhead ground wire of Huainan~Wannan~Zhebei~Huxi 1000 kV UHV AC double-circuit transmission line
    Li, Bao-Ju
    Zhou, Hao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (10): : 86 - 89
  • [18] Calculation of short-circuit current distribution between OPGW and ordinary ground wire under single-phase earth fault occurred in transmission system simultaneously configuring both kinds of ground wires
    Xu, Gaoxiong
    Zhao, Daping
    Qi, Liyan
    Ding, Huixia
    Jia, Meijian
    Zhang, Yu
    Dianwang Jishu/Power System Technology, 2011, 35 (01): : 229 - 232
  • [19] Current limiting performance test of 3-phase tri-axial transformer-type SFCL with re-wound structure at 3-line-to-ground fault in lab-scale transmission system
    Shirai, Yasuyuki
    Noda, Sho
    Yamabe, Kenta
    Hattori, Keisuke
    Baba, Jumpei
    Kobayashi, Shinichi
    Sato, Kenichi
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2013, 484 : 248 - 252