CONTINUOUS CARDIAC-OUTPUT MONITORING BY THE FICK METHOD

被引:4
|
作者
BAXLEY, WA [1 ]
CAVENDER, JB [1 ]
KNOBLOCK, J [1 ]
机构
[1] UNIV ALABAMA, MED CTR, BIRMINGHAM, AL 35294 USA
来源
关键词
FIBEROPTIC CATHETERS; METABOLIC ANALYSIS; OXYGEN CONSUMPTION;
D O I
10.1002/ccd.1810280118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Current methods for longitudinal assessment of cardiac output in severely ill patients are intermittent only and in many respects appear unsatisfactory. We have developed a computerized on-line system for continuous Fick cardiac output monitoring, utilizing fiberoptic arterial and pulmonary arterial probes with a metabolic analyzer for VO2. In 15 patients, cardiac output ranged 1.9-6.8 L/min and 12 were within 5% of thermodilution values. Continuous output monitoring during interventions in two patients (saline infusion and coronary angioplasty) illustrate the utility of the technique. Two additional patients had unsatisfactory VO2 data due to low airflow velocity. The results of this pilot study suggest that cardiac output monitoring by the Fick method may have clinical and investigational uses in intensive care units and during cardiac catheterization or surgical procedures.
引用
收藏
页码:89 / 92
页数:4
相关论文
共 50 条
  • [1] CONTINUOUS FICK CARDIAC-OUTPUT COMPARED TO THERMODILUTION CARDIAC-OUTPUT
    DAVIES, GG
    JEBSON, PJR
    GLASGOW, BM
    HESS, DR
    CRITICAL CARE MEDICINE, 1986, 14 (10) : 881 - 885
  • [2] MEASURING CONTINUOUS FICK CARDIAC-OUTPUT
    STENGELE, E
    KROZINGEN, B
    CHEST, 1995, 107 (06) : 1773 - 1774
  • [3] CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT BY THE FICK PRINCIPLE - COMPARISON WITH THE THERMODILUTION METHOD
    WIPPERMANN, CF
    HUTH, R
    SCHRANZ, D
    MICHELBEHNKE, I
    OELERT, H
    PEDIATRIC RESEARCH, 1994, 36 (01) : A64 - A64
  • [4] CONTINUOUS ON LINE CARDIAC-OUTPUT BY FICK METHOD FOR USE IN ICU PATIENTS
    TACCHINO, RM
    GIOVANNINI, I
    CASTAGNETO, M
    CRITICAL CARE MEDICINE, 1986, 14 (04) : 400 - 400
  • [5] COMPARISON OF CONTINUOUS ESOPHAGEAL DOPPLER CARDIAC-OUTPUT WITH CONTINUOUS FICK CARDIAC-OUTPUT DURING HEMORRHAGE IN PIGS
    JOHNSON, B
    DAVIES, G
    KAMAL, G
    STARR, J
    CRITICAL CARE MEDICINE, 1987, 15 (04) : 365 - 365
  • [6] CONTINUOUS CARDIAC-OUTPUT COMPUTER EMPLOYING THE FICK PRINCIPLE
    NEUHOF, H
    GLASER, E
    KOCH, HU
    WOLF, H
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1978, 14 (06): : P114 - P116
  • [7] CONTINUOUS MONITORING OF CARDIAC-OUTPUT
    SAADJIAN, A
    TORRESANI, J
    QUERCY, JF
    AMICHOT, JL
    JOUVE, A
    LACROIX, Y
    NOUVELLE PRESSE MEDICALE, 1972, 1 (32): : 2113 - +
  • [8] CONTINUOUS MONITORING OF CARDIAC-OUTPUT
    MACKAY, RS
    HECHTMAN, HB
    BIOTELEMETRY, 1974, 1 (01) : 21 - 30
  • [9] CLARIFYING THE ROLE OF CONTINUOUS FICK CARDIAC-OUTPUT MEASUREMENT DURING EXERCISE
    LUMB, PD
    CHEST, 1993, 104 (02) : 332 - 333
  • [10] CONTINUOUS CARDIAC-OUTPUT - FICK PRINCIPLE VS PULSE CONTOUR ANALYSIS
    SPECHT, M
    SPIES, CD
    WIRBELAUER, C
    APENBURG, C
    HANNEMANN, L
    REINHART, K
    ANESTHESIA AND ANALGESIA, 1993, 76 (02): : S416 - S416