DETERMINATION OF CICLETANINE ENANTIOMERS IN PLASMA BY HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS

被引:72
作者
PRUNONOSA, J
OBACH, R
DIEZCASCON, A
GOUESCLOU, L
机构
[1] BECKMAN INSTRUMENTS SPAIN,BARCELONA,SPAIN
[2] BECKMAN INSTRUMENTS FRANCE,GAGNY,FRANCE
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 574卷 / 01期
关键词
D O I
10.1016/0378-4347(92)80106-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective high-performance capillary electrophoresis procedure was developed for the determination of S(+) and R(-) enantiomers of cicletanine in human plasma. The procedure consisted in extraction of the drug with diethyl ether and analysis by micellar electrokinetic capillary chromatography in a fused-silica capillary using gamma-cyclodextrins in the run buffers and ultraviolet detection. The method was linear from 10 to 500 ng/ml and the limit of detection was 10 ng/ml for each enantiomer in plasma samples. The within-run precision of the method, expressed as relative standard deviation, was 10.4 and 9.6% at 25 ng/ml for S(+) and R(-) cicletanine, and 4.2 and 4.6% at 500 ng/ml, respectively. This method has been used to follow the time course of the concentrations of the cicletanine enantiomers in human plasma after a single therapeutic dose of cicletanine given by mouth.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 7 条
[1]  
Chabrier P. E., 1988, CARDIOVASC DRUG REV, V6, P166
[2]   SEPARATION OF OPTICAL ISOMERS BY CAPILLARY ZONE ELECTROPHORESIS BASED ON HOST GUEST COMPLEXATION WITH CYCLODEXTRINS [J].
FANALI, S .
JOURNAL OF CHROMATOGRAPHY, 1989, 474 (02) :441-446
[3]  
Fanali S., 1989, J MICROCOLUMN SEP, V1, P190, DOI DOI 10.1002/MCS.1220010406
[4]   USE OF COMPLEXING AGENTS FOR SELECTIVE SEPARATION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS - CHIRAL RESOLUTION VIA CYCLODEXTRINS INCORPORATED WITHIN POLYACRYLAMIDE-GEL COLUMNS [J].
GUTTMAN, A ;
PAULUS, A ;
COHEN, AS ;
GRINBERG, N ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1988, 448 (01) :41-53
[5]   SEPARATION OF RACEMATES BY CAPILLARY ZONE ELECTROPHORESIS BASED ON COMPLEXATION WITH CYCLODEXTRINS [J].
TANAKA, M ;
ASANO, S ;
YOSHINAGO, M ;
KAWAGUCHI, Y ;
TETSUMI, T ;
SHONO, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (01) :63-64
[6]   ELECTROKINETIC SEPARATIONS WITH MICELLAR SOLUTIONS AND OPEN-TUBULAR CAPILLARIES [J].
TERABE, S ;
OTSUKA, K ;
ICHIKAWA, K ;
TSUCHIYA, A ;
ANDO, T .
ANALYTICAL CHEMISTRY, 1984, 56 (01) :111-113
[7]   FREE SOLUTION CAPILLARY ELECTROPHORESIS AND MICELLAR ELECTROKINETIC RESOLUTION OF AMINO-ACID ENANTIOMERS AND PEPTIDE ISOMERS WITH L-MARFEYS AND D-MARFEYS REAGENTS [J].
TRAN, AD ;
BLANC, T ;
LEOPOLD, EJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :241-249