Computed tomography enterography in assessment of Crohn's disease activity

被引:1
|
作者
Ibrahim, Enas Abdel Ghany [1 ]
El-Dieb, Leila Rawash [1 ]
Chalabi, Nivine [1 ]
Osman, Noha Mohamed [1 ]
机构
[1] Ain Shams Univ, Fac Med, Dept Radiodiag, Cairo, Egypt
关键词
Crohn's disease; CT enterography; Ileocolonoscopy;
D O I
10.1016/j.ajme.2014.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Monitoring the disease activity in Crohn's disease (CD) may be challenging with endoscopic manoeuvers due to difficulties in reaching the affected areas and being restricted to mucosal lesions, so the existence of a more tolerable and reliable technique will be highly warranted. Objectives: This study aims at detection of CD's activity by computed tomography enterography (CTE) in correlation with ileocolonoscopy evaluation as well as detection of extra-enteric manifestations and complications of the disease. Materials and methods: Twenty-four patients who were clinically and histopathologically proven as CD patients were retrospectively included in this study. Patients were divided into active and inactive groups according to ileocolonoscopic evaluation. All patients underwent CTE as clinically indicated within 1 week of ileocolonoscopy. Radiological parameters suggestive of Crohn's disease activity at CTE were interpreted at the terminal ileum and correlated to the corresponding ileocolonoscopy reports for signs of CD activity. Extra-enteric findings and complications of CD were also reported if present. Results: CTE was accurate in detecting CD activity in 15 out of 18 active cases (active group) and in detecting disease inactivity in 5 out of 6 inactive cases (inactive group) with sensitivity and specificity of 83.3%. Mural hyperenhancement was the most distinguished sign of CD activity in CTE. Conclusion: CTE is a non invasive and reliable technique that has a significant value in assessment of CD activity in correlation with endoscopy, hence, it is useful in follow up and preoperative guidance. (C) 2014 Alexandria University Faculty of Medicine. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [1] Prospective Comparison of Computed Tomography Enterography and Magnetic Resonance Enterography for Assessment of Disease Activity and Complications in Ileocolonic Crohn's Disease
    Fiorino, G.
    Bonifacio, C.
    Peyrin-Biroulet, L.
    Minuti, F.
    Repici, A.
    Spinelli, A.
    Fries, W.
    Balzarini, L.
    Montorsi, M.
    Malesci, A.
    Danese, S.
    INFLAMMATORY BOWEL DISEASES, 2011, 17 (05) : 1073 - 1080
  • [2] Contrast-enhanced ultrasound in the assessment of Crohn's disease activity: comparison with computed tomography enterography
    Ding, Shi-Si
    Liu, Chang
    Zhang, Yi-Feng
    Sun, Li-Ping
    Xiang, Li-Hua
    Liu, Hui
    Fang, Yan
    Ren, Wei-Wei
    Zhao, Hui
    Sun, Xiao-Min
    Zhang, Kun
    Zhang, Chang-Bao
    Xu, Xiao-Rong
    Xu, Hui-Xiong
    RADIOLOGIA MEDICA, 2022, 127 (10): : 1068 - 1078
  • [3] Computed Tomography Enterography: Quantitative Evaluation on Crohn's Disease Activity
    Cheng, Jingyun
    Xie, Hui
    Yang, Hao
    Wang, Ke
    Xu, Guobin
    Wu, Guangyao
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [4] Monitoring Crohn's disease activity: endoscopy, fecal markers and computed tomography enterography
    Lopes, Susana
    Andrade, Patricia
    Afonso, Joana
    Cunha, Rui
    Rodrigues-Pinto, Eduardo
    Ramos, Isabel
    Macedo, Guilherme
    Magro, Fernando
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2018, 11
  • [5] Contrast-enhanced ultrasound in the assessment of Crohn’s disease activity: comparison with computed tomography enterography
    Shi-Si Ding
    Chang Liu
    Yi-Feng Zhang
    Li-ping Sun
    Li-Hua Xiang
    Hui Liu
    Yan Fang
    Wei-Wei Ren
    Hui Zhao
    Xiao-Min Sun
    Kun Zhang
    Chang-Bao Zhang
    Xiao-Rong Xu
    Hui-Xiong Xu
    La radiologia medica, 2022, 127 : 1068 - 1078
  • [6] Structured Reporting of Computed Tomography Enterography in Crohn's Disease
    Zhu, Hui
    Chen, Suying
    Chen, Jinghao
    Yang, Jushun
    Cong, Ruochen
    Sun, Jinjie
    Xu, Yachun
    He, Bosheng
    CURRENT MEDICAL IMAGING, 2024, 20
  • [7] Prediction of Perianal Fistula in Crohn's Disease by Computed Tomography Enterography
    Ni, Genghuan
    Zhao, Hongwei
    Shen, Haiyan
    Li, Senjuan
    Ao, Weiqun
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2024, 35 (03): : 168 - 177
  • [8] A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn's Disease
    Xiao, Wei-xiong
    Zhu, Yu-ting
    Zhang, Zhi-chao
    Luo, Min
    Ma, Ming-ping
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 7051 - 7058
  • [9] Efficiency of dual-energy computed tomography enterography in the diagnosis of Crohn’s disease
    Jinghao Chen
    Jie Zhou
    Jushun Yang
    Ruochen Cong
    Jinjie Sun
    Jing Xiao
    Jianhua Shi
    Bosheng He
    BMC Medical Imaging, 21
  • [10] Efficiency of dual-energy computed tomography enterography in the diagnosis of Crohn's disease
    Chen, Jinghao
    Zhou, Jie
    Yang, Jushun
    Cong, Ruochen
    Sun, Jinjie
    Xiao, Jing
    Shi, Jianhua
    He, Bosheng
    BMC MEDICAL IMAGING, 2021, 21 (01)