ANALYTE VOLATILIZATION PROCEDURE FOR THE DETERMINATION OF LOW CONCENTRATIONS OF IODINE BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY

被引:24
作者
NAKAHARA, T
MORI, T
机构
[1] Department of Applied Chemistry, University of Osaka Prefecture, Sakai
关键词
INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; IODINE DETERMINATION; ANALYTE VOLATILIZATION; GAS-PHASE SAMPLE INTRODUCTION; BRINE SAMPLE;
D O I
10.1039/ja9940900159
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method is described for the generation of a continuous flow of volatile iodine by the oxidation of aqueous iodide for the determination of low concentrations of iodine by inductively coupled plasma (ICP) atomic emission spectrometry in the normal ultraviolet and vacuum ultraviolet (VUV) regions of the spectrum. For measuring spectral lines in the VUV region, the monochromator and the enclosed external optical path between the ICP source and the entrance slit of the monochromator were both purged with nitrogen to minimize light absorption by atmospheric oxygen. The iodine atom emission lines at 178.28, 183.04 and 206.16 nm were selected as the analytical lines of interest. Of the various oxidation reactions investigated, an oxidizing solution of 5.0 mmol l-1 of sodium nitrite in 8.0 mol l-1 sulfuric acid was found to be the most appropriate for the generation of elemental iodine. The gaseous iodine is separated from the solution in a simple gas-liquid separator and swept into the argon stream of an ICP for analysis. The best attainable detection limits (3sigma criterion) for iodine at 178.28, 183.04 and 206.16 nm were found to be 0.39, 0.55 and 2.1 ng ml-1, respectively. Typical calibration graphs obtained under the optimized experimental conditions are rectilinear over approximately four orders of magnitude of concentration. The present method has successfully been applied to the determination of total iodine (i.e., iodide + iodate) in several brine samples.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 19 条
[1]   ELECTROTHERMAL VAPORIZATION SAMPLE INTRODUCTION INTO AN ATMOSPHERIC-PRESSURE HELIUM MICROWAVE-INDUCED PLASMA FOR THE DETERMINATION OF IODINE IN HYDROCHLORIC-ACID [J].
BARNETT, NW ;
KIRKBRIGHT, GF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (05) :337-342
[2]   SAMPLE INTRODUCTION - THE ACHILLES HEEL OF ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A786-&
[3]   CHEMICAL GENERATION OF CHLORINE, BROMINE, AND IODINE FOR SAMPLE INTRODUCTION INTO A SURFATRON-GENERATED ARGON MICROWAVE-INDUCED PLASMA [J].
CALZADA, MD ;
QUINTERO, MC ;
GAMERO, A ;
GALLEGO, M .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1374-1378
[5]   DETERMINATION OF I-129 IN VEGETABLE SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
COX, RJ ;
PICKFORD, CJ ;
THOMPSON, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :635-640
[6]   ONLINE PRECONCENTRATION AND VOLATILIZATION OF IODINE FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
DOLAN, SP ;
SINEX, SA ;
CAPAR, SG ;
MONTASER, A ;
CLIFFORD, RH .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2539-2542
[7]   INSTRUMENTAL AND RADIOCHEMICAL NEUTRON-ACTIVATION ANALYSIS OF TRACE IODINE IN GEOLOGICAL SAMPLES [J].
EBIHARA, M ;
SAITO, N ;
AKAIWA, H ;
TOMURA, K .
ANALYTICAL SCIENCES, 1992, 8 (02) :183-187
[8]  
GAYDON AG, 1974, SPECTROSCOPY FLAMES, P351
[9]   SPECTROPHOTOMETRIC DETERMINATION OF IODIDE AT THE 10-6 MOL I-1 LEVEL BY SOLVENT-EXTRACTION WITH METHYLENE-BLUE [J].
KOH, T ;
ONO, M ;
MAKINO, I .
ANALYST, 1988, 113 (06) :945-948
[10]   DIRECT DETERMINATION OF NONMETALS IN SOLUTION WITH ATOMIC SPECTROMETRY [J].
MCGREGOR, DA ;
CULL, KB ;
GEHLHAUSEN, JM ;
VISCOMI, AS ;
WU, MG ;
ZHANG, LM ;
CARNAHAN, JW .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :A1089-&