Ventilative Cooling in a School Building: Evaluation of the Measured Performances

被引:13
作者
Breesch, Hilde [1 ]
Merema, Bart [1 ]
Versele, Alexis [1 ]
机构
[1] Katholieke Univ Leuven, Dept Civil Engn, Construct Technol Cluster, Sustainable Bldg,Technol Campus Ghent, B-9000 Ghent, Belgium
关键词
ventilative cooling; nearly zero-energy buildings (nZEB); school building; measurements; thermal comfort;
D O I
10.3390/fluids3040068
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The test lecture rooms on Katholieke Universiteit Leuven (KU Leuven) Ghent Technology Campus (Belgium) are a demonstration case of Annex 62: Ventilative Cooling of the International Energy Agency's Energy in Buildings and Communities programme (IEA EBC). The building is cooled by natural night ventilation and indirect evaporative cooling (IEC). Thermal comfort and the performances of ventilative cooling are evaluated. Long-term measurements of internal temperatures, occupancy, opening of windows and IEC were carried out in the cooling season of 2017. The airflow rates through the windows in cross- and single-sided ventilation mode were measured by both tracer gas concentration decay and air velocity measurements. In addition, the air flow pattern is visualized by measuring air temperatures in the room. The results show that good thermal summer comfort was measured except during heat waves and/or periods with high occupancy. Both nighttime ventilation and IEC operate very well. IEC can lower the supply temperature by day significantly compared to the outdoor temperature. The Air Changes Rates (ACR) of the night ventilation greatly depends on wind direction and velocity. The air temperature profile showed that the air is cooled down in the whole lecture but more in the upper zone. The extensive data monitoring system was important to detect malfunctions and to optimize the whole building performance.
引用
收藏
页数:14
相关论文
共 29 条
[1]  
Andriamamonjy A., 2015, P 36 AIVC C MADR SPA
[2]  
[Anonymous], 2007, 15251 EN
[3]  
[Anonymous], 2001, 12569 EN ISO
[4]   Impact of climate warming on passive night cooling potential [J].
Artmann, N. ;
Gyalistras, D. ;
Manz, H. ;
Heiselberg, P. .
BUILDING RESEARCH AND INFORMATION, 2008, 36 (02) :111-128
[5]   Climatic potential for passive cooling of buildings by night-time ventilation in Europe [J].
Artmann, N. ;
Manz, H. ;
Heiselberg, P. .
APPLIED ENERGY, 2007, 84 (02) :187-201
[6]   Night ventilation for building cooling in summer [J].
Blondeau, P ;
Sperandio, M ;
Allard, F .
SOLAR ENERGY, 1997, 61 (05) :327-335
[7]   Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis [J].
Breesch, H. ;
Janssens, A. .
SOLAR ENERGY, 2010, 84 (08) :1453-1467
[8]  
Breesch H., 2016, REHVA J, V53, P17
[9]   Thermal effectiveness characteristics of low approach indirect evaporative cooling systems in buildings [J].
Costelloe, B. ;
Finn, D. .
ENERGY AND BUILDINGS, 2007, 39 (12) :1235-1243
[10]  
Decrock D., 2017, EVALUATION COOLING P