FATIGUE FAILURE OF COMPOSITE BOLTED JOINTS

被引:33
|
作者
HERRINGTON, PD [1 ]
SABBAGHIAN, M [1 ]
机构
[1] LOUISIANA STATE UNIV,DEPT MECH ENGN,BATON ROUGE,LA 70803
关键词
FATIGUE; GRAPHITE EPOXY; BEARING STRENGTH; BOLTED JOINTS;
D O I
10.1177/002199839302700503
中图分类号
TB33 [复合材料];
学科分类号
摘要
The effects of a number of parameters on the fatigue characteristics of a bolted graphite/epoxy composite laminate are investigated. In particular, tests were performed in order to study the influence of three independent parameters: applied stress level, orientation of the outer layer reinforcing filaments, and the bolt torque level on the fatigue life of a graphite/epoxy composite. Analysis of variance and censoring techniques were used to analyze the experimentally obtained data. Fatigue life data was determined to be adequately characterized by using a log-normal distribution.
引用
收藏
页码:491 / 512
页数:22
相关论文
共 50 条
  • [1] Spectrum fatigue of composite bolted joints
    Schön, J
    Nyman, T
    INTERNATIONAL JOURNAL OF FATIGUE, 2002, 24 (2-4) : 273 - 279
  • [2] Fatigue evaluation of composite bolted and bonded joints
    Whitworth, HA
    JOURNAL OF ADVANCED MATERIALS, 1998, 30 (02): : 25 - 31
  • [3] ELASTOPLASTIC FAILURE ANALYSIS OF COMPOSITE BOLTED JOINTS
    TSUJIMOTO, Y
    WILSON, D
    JOURNAL OF COMPOSITE MATERIALS, 1986, 20 (03) : 236 - 252
  • [4] Failure Behavior of Composite Bolted Joints: Review
    El-Sisi, Alaa
    Hassanin, Ahmed
    Alsharari, Fahad
    Galustanian, Narek
    Salim, Hani
    CIVILENG, 2022, 3 (04): : 1061 - 1076
  • [5] Fatigue bearing failure of CFRP composite in biaxially loaded bolted joints at elevated temperature
    Kapidzic, Zlatan
    Ansell, Hans
    Schon, Joakim
    Simonsson, Kjell
    COMPOSITE STRUCTURES, 2015, 127 : 298 - 307
  • [6] Damage and failure mechanisms in composite bolted joints
    Bau, H
    Joining and Repair of Composite Structures, 2004, : 182 - 198
  • [7] Failure analysis of bolted joints in composite laminates
    1600, Publ by ASTM, Philadelphia, PA, USA
  • [8] Fatigue characteristics of the bolted joints for unidirectional composite laminates
    Lim, TS
    Kim, BC
    Lee, DG
    COMPOSITE STRUCTURES, 2006, 72 (01) : 58 - 68
  • [9] FRETTING FATIGUE FAILURE IN FRICTION GRIP BOLTED JOINTS
    SPIERS, R
    CULLIMOR.MS
    JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1968, 10 (05): : 434 - &
  • [10] Effect of interference installation method on interfacial properties and fatigue failure behavior of bolted composite joints
    Wang, Xiaohe
    Cao, Zengqiang
    Guo, Yingjiang
    JOURNAL OF COMPOSITE MATERIALS, 2024, 58 (13) : 1537 - 1554