IDENTIFICATION OF PATIENTS WITH VENTRICULAR-TACHYCARDIA AFTER MYOCARDIAL-INFARCTION BY HIGH-RESOLUTION MAGNETOCARDIOGRAPHY AND ELECTROCARDIOGRAPHY

被引:25
|
作者
MAKIJARVI, M [1 ]
MONTONEN, J [1 ]
TOIVONEN, L [1 ]
SILTANEN, P [1 ]
NIEMINEN, MS [1 ]
LEINIO, M [1 ]
KATILA, T [1 ]
机构
[1] HELSINKI UNIV TECHNOL,BIOMED ENGN LAB,SF-02150 ESPOO 15,FINLAND
关键词
HIGH-RESOLUTION; MAGNETOCARDIOGRAPHY; MYOCARDIAL INFARCTION; VENTRICULAR TACHYCARDIA;
D O I
10.1016/0022-0736(93)90003-V
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The value of time domain analysis of late fields in the high-resolution magnetocardiogram in the identification of myocardial infarction patients with ventricular tachycardia was investigated in 30 subjects: 10 patients with documented sustained ventricular tachycardia and old myocardial infarction, 10 patients with old myocardial infarction without complex ventricular arrhythmias, and 10 normal volunteers. The duration of the QRS complex in the magnetocardiogram was significantly longer in ventricular tachycardia patients compared to myocardial infarction patients (144 (SD, 33) vs 109 (SD, 8) ms; p = 0.004). The root-mean-square field of the last 60 ms of the QRS complex was smaller in ventricular tachycardia patients than in myocardial infarction patients (830 (SD, 650) vs 1,480 (SD, 730) fT, respectively; p = 0.047). Also, the duration of the low-amplitude signal less than 700 fT was longer in ventricular tachycardia patients than in myocardial infarction patients (47 (SD, 28) vs 28 (SD, 8) ms, respectively; p = 0.048). The sensitivity and specificity in identifying ventricular tachycardia patients were both 80%, and the positive and negative predictive values were 78% and 86%, respectively. High-resolution electrocardiography recorded during the same session performed slightly better: sensitivity 90%, specificity 90%, and positive and negative predictive values 90%. The signal-to-noise ratio of electrocardiogram was higher (approximately 2 x) than that of magnetocardiogram. It is concluded that the new magnetocardiographic technique seems helpful in screening patients at risk of ventricular arrhythmias after myocardial infarction. The results encourage further refinement of the technique and application in prospective studies.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 50 条
  • [31] RISK STRATIFICATION AND PROGNOSIS OF PATIENTS TREATED WITH AMIODARONE FOR MALIGNANT VENTRICULAR TACHYARRHYTHMIAS AFTER MYOCARDIAL-INFARCTION
    PROCLEMER, A
    FACCHIN, D
    VANUZZO, D
    FERUGLIO, GA
    CARDIOVASCULAR DRUGS AND THERAPY, 1993, 7 (04) : 683 - 689
  • [32] INDUCTION OF TRANSIENT 3RD-DEGREE ATRIOVENTRICULAR-BLOCK DURING RADIOFREQUENCY CATHETER ABLATION IN A PATIENT WITH VENTRICULAR-TACHYCARDIA AND REMOTE MYOCARDIAL-INFARCTION
    KOTTKAMP, H
    CHEN, X
    HINDRICKS, G
    WILLEMS, S
    HAVERKAMP, W
    WICHTER, T
    BREITHARDT, G
    BORGGREFE, M
    EUROPEAN HEART JOURNAL, 1995, 16 (05) : 647 - 650
  • [33] CARDIAC ANATOMY AND VENTRICULAR LOADING AFTER MYOCARDIAL-INFARCTION
    ANVERSA, P
    OLIVETTI, G
    MEGGS, LG
    SONNENBLICK, EH
    CAPASSO, JM
    CIRCULATION, 1993, 87 (06) : 22 - 27
  • [34] Non-contact mapping in the treatment of ventricular tachycardia after myocardial infarction
    Kim Rajappan
    Richard J. Schilling
    Journal of Interventional Cardiac Electrophysiology, 2007, 19 : 9 - 18
  • [35] Influence of standard modifiable risk factors on ventricular tachycardia after myocardial infarction
    Deshmukh, Tejas
    Kovoor, Joshua G.
    Byth, Karen
    Chow, Clara K.
    Zaman, Sarah
    Chong, James J. H.
    Figtree, Gemma A.
    Thiagalingam, Aravinda
    Kovoor, Pramesh
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [36] Ventricular tachycardia because of myocardial infarction after COVID-19 vaccination
    Lee, Dan-Ying
    Lin, Chin-Yu
    Huang, Shao-Sung
    JOURNAL OF ARRHYTHMIA, 2022, 38 (05) : 824 - 826
  • [37] Successful Epicardial Catheter Ablation of a Septal Ventricular Tachycardia after Myocardial Infarction
    Yamada, Takumi
    Doppalapudi, Harish
    McElderry, H. Thomas
    Plumb, Vance J.
    Kay, G. Neal
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (05): : e116 - e119
  • [38] Non-contact mapping in the treatment of ventricular tachycardia after myocardial infarction
    Rajappan, Kim
    Schilling, Richard J.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2007, 19 (01) : 9 - 18
  • [39] Correlation between substrate location and ablation strategy in patients with ventricular tachycardia late after myocardial infarction
    Yoshiga, Yasuhiro
    Mathew, Shibu
    Wissner, Erik
    Tilz, Roland
    Fuernkranz, Alexander
    Metzner, Andreas
    Rillig, Andreas
    Konstantinidou, Melanie
    Igarashi, Miyako
    Kuck, Karl-Heinz
    Ouyang, Feifan
    HEART RHYTHM, 2012, 9 (08) : 1192 - 1199
  • [40] Radiofrequency catheter ablation of ventricular tachycardia after myocardial infarction
    Stevenson, WG
    Friedman, PL
    Kocovic, D
    Sager, PT
    Saxon, LA
    Pavri, B
    CIRCULATION, 1998, 98 (04) : 308 - 314