OPTICAL-COHERENCE TOMOGRAPHY OF A DENSE TISSUE - STATISTICS OF ATTENUATION AND BACKSCATTERING

被引:271
作者
SCHMITT, JM
KNUTTEL, A
YADLOWSKY, M
ECKHAUS, MA
机构
[1] NHLBI,CELLULAR BIOL LAB,BETHESDA,MD 20892
[2] NIH,NATL CTR RES RESOURCES,VET RESOURCES PROGRAM,BETHESDA,MD 20892
关键词
D O I
10.1088/0031-9155/39/10/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper addresses fundamental issues that underlie the interpretation of images acquired from turbid tissues by optical-coherence tomography (OCT). The attenuation and backscattering properties of freshly excised rat arteries and their dependence on the focusing and collection optics of the ocr system were measured at two wavelengths in the near infrared (830 nm and 1300 nm). Determined from the ratio of the magnitudes of the reflections from glass plates placed on both sides of the arteries, the mean attenuation coefficient of the arterial wall was found to be in the range 14 < mu(t) < 22 mm(-1) at 830 nm and 11 < mu(t) < 20 mm(-1) at 1300 nm. The measured values of mu(t) were lowest for the longer source wavelength and for probe beams with the smallest average diameters. The observed dependence of mu(t), on beam size indicates that relatively large-scale Variations in the index of refraction of the tissue contributed to degradation of the tranverse spatial coherence of the beam. We introduce a framework for understanding and quantifying beam-size effects by way of the mutual-coherence function. The fact that spatial variations in backscattering and attenuation (which includes spatial-coherence losses) have similar effects on OCT signals makes the origin of the signals difficult to determine. Evidence is given that suggests that, in spite of this difficulty, certain features of microstructures embedded several hundred micrometres deep in a turbid tissue can still be detected and characterized.
引用
收藏
页码:1705 / 1720
页数:16
相关论文
共 19 条
  • [1] FIRST-ORDER AND SECOND-ORDER BACKSCATTERING FROM CLOUDS ILLUMINATED BY FINITE BEAMS
    ANDERSON, RC
    BROWELL, EV
    [J]. APPLIED OPTICS, 1972, 11 (06): : 1345 - &
  • [2] Born M., 1983, PRINCIPLES OPTICS
  • [3] MONOSTATIC HETERODYNE LIDAR PERFORMANCE - THE EFFECT OF THE TURBULENT ATMOSPHERE
    CLIFFORD, SF
    WANDZURA, S
    [J]. APPLIED OPTICS, 1981, 20 (03): : 514 - 516
  • [4] HIGH-RESOLUTION REFLECTOMETRY IN BIOLOGICAL TISSUES
    CLIVAZ, X
    MARQUISWEIBLE, F
    SALATHE, RP
    NOVAK, RP
    GILGEN, HH
    [J]. OPTICS LETTERS, 1992, 17 (01) : 4 - 6
  • [5] EYE-LENGTH MEASUREMENT BY INTERFEROMETRY WITH PARTIALLY COHERENT-LIGHT
    FERCHER, AF
    MENGEDOHT, K
    WERNER, W
    [J]. OPTICS LETTERS, 1988, 13 (03) : 186 - 188
  • [6] COHERENT LASER-RADAR PERFORMANCE FOR GENERAL ATMOSPHERIC REFRACTIVE TURBULENCE
    FREHLICH, RG
    KAVAYA, MJ
    [J]. APPLIED OPTICS, 1991, 30 (36): : 5325 - 5352
  • [7] HITZENBERGER CK, 1991, INVEST OPHTH VIS SCI, V32, P616
  • [8] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [9] HETERODYNE-DETECTION THROUGH RAIN, SNOW, AND TURBID MEDIA - EFFECTIVE RECEIVER SIZE AT OPTICAL THROUGH MILLIMETER WAVELENGTHS
    KAZOVSKY, LG
    KOPEIKA, NS
    [J]. APPLIED OPTICS, 1983, 22 (05) : 706 - 710
  • [10] ATMOSPHERIC DEGRADATION OF ELECTROOPTICAL SYSTEM PERFORMANCE
    LUTOMIRSKI, RF
    [J]. APPLIED OPTICS, 1978, 17 (24): : 3915 - 3921