MAPPING OF THE RADIO-FREQUENCY MAGNETIC-FIELD WITH A MR SNAPSHOT FLASH TECHNIQUE

被引:57
作者
KLOSE, U [1 ]
机构
[1] UNIV TUBINGEN,DEPT MED PHYS,W-7400 TUBINGEN 1,GERMANY
关键词
D O I
10.1118/1.596828
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A fast method to measure the radio frequency magnetic field intensity distribution during magnetic resonance examinations within objects or patients is proposed. Using a snapshot FLASH sequence, several images are obtained with different transmitter amplitudes for the single prepulse prior to the imaging sequence. The signal intensity at each pixel within a selected slice is diminished by this prepulse, unless the pulse angle is 0-degrees or a multiple of 360-degrees. This condition can be used to measure that transmitter amplitude U(max) for each pixel which causes an excitation of 360-degrees by the prepulse. The values of U(max) can be visualized in an image and are inversely proportional to the radio frequency magnetic field strength at each position within the image. The method can also be used for in-vivo measurements, where it may be difficult to realize prepulses with sufficient high flip angles. In these cases, signal corresponding to a 180-degrees prepulse can be used for calculating U(max).
引用
收藏
页码:1099 / 1104
页数:6
相关论文
共 13 条
[1]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[2]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[3]   THE MODIFICATION OF THE RF FIELD DISTRIBUTION OF SURFACE COILS BY WEAKLY CONDUCTING SALINE SAMPLES [J].
HANSTOCK, CC ;
LUNT, JA ;
ALLEN, PS .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (02) :204-209
[4]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[5]   VARIATION OF CONTRAST BETWEEN DIFFERENT BRAIN-TISSUES WITH AN MR SNAPSHOT TECHNIQUE [J].
KLOSE, U ;
NAGELE, T ;
GRODD, W ;
PETERSEN, D .
RADIOLOGY, 1990, 176 (02) :578-581
[6]  
KLOSE U, 1989, 9TH P M SOC MAGN RES, P1047
[7]  
LEROUX P, 1988, 8TH P M SOC MAGN RES, P1049
[8]   PLANAR SPIN IMAGING BY NMR [J].
MANSFIELD, P ;
MAUDSLEY, AA .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1976, 9 (15) :L409-&
[9]   PHASE AND SENSITIVITY OF RECEIVER COILS IN MAGNETIC-RESONANCE-IMAGING [J].
MCVEIGH, ER ;
BRONSKILL, MJ ;
HENKELMAN, RM .
MEDICAL PHYSICS, 1986, 13 (06) :806-814
[10]   SELECTIVE EXCITATION IN FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE [J].
MORRIS, GA ;
FREEMAN, R .
JOURNAL OF MAGNETIC RESONANCE, 1978, 29 (03) :433-462