EFFECT OF GD-DTPA-BMA ON MAGNETIZATION TRANSFER - APPLICATION TO RAPID IMAGING OF CARDIAC ISCHEMIA

被引:16
作者
JONES, RA
HARALDSETH, O
SCHJOTT, J
BRUROK, H
JYNGE, P
OKSENDAL, AN
RINCK, PA
机构
[1] MR Center, Natural Sciences Section (Sintef/Unimed), Trondheim
[2] Institute for Pharmacology and Toxicology, University of Trondheim
[3] Nycomed Imaging AS, Oslo
[4] MR Center, Trondheim
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1993年 / 3卷 / 01期
关键词
CONTRAST ENHANCEMENT; GADOLINIUM; HEART; MR; MAGNETIZATION TRANSFER CONTRAST; MYOCARDIUM; INFARCTION; ISCHEMIA; PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1002/jmri.1880030108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The addition of a paramagnetic contrast agent reduces the magnetization transfer effect between the free and restricted proton pools in both agar phantoms and cardiac muscle tissue. This reduction is due to the reduction in the intrinsic T1 of the free proton pool and increases the signal observed after a given magnetization transfer sequence. Images of ex vivo piglet hearts were obtained with a segmented snapshot FLASH (fast low-angle shot) sequence with a 128 x 128 matrix, four segments, and two signals averaged, resulting in an imaging time of 7 seconds. Magnetization transfer was induced by applying a DANTE (delays alternating with nutations for tailored excitations) pulse sequence in the intersegment interval. This was an efficient method of inducing magnetization transfer because it excites the restricted proton pool across the full frequency spectrum. Ischemia due to occlusion of the left anterior descending branch of the coronary artery could be visualized after infusion of gadolinium diethylenetriaminepentaacetic acid-bis(methylamide) (DTPA-BMA). Although the ischemia could be seen with the basic sequence, the contrast between ischemic and non-ischemic tissue improved when the magnetization transfer sequence was included. The most marked improvements in magnetization transfer were achieved with low doses of Gd-DTPA-BMA.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 23 条
  • [21] Contrast-free high-resolution 3D magnetization transfer imaging for simultaneous myocardial scar and cardiac vein visualization
    Lopez, Karina
    Neji, Radhouene
    Mukherjee, Rahul K.
    Whitaker, John
    Phinikaridou, Alkystis
    Razavi, Reza
    Prieto, Claudia
    Roujol, Sebastien
    Botnar, Rene
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (05) : 627 - 640
  • [22] T2-Weighted Magnetic Resonance Imaging of the Liver: Evaluation of the Effect in Signal Intensity After Gd-EOB-DTPA Enhancement
    Tamada, Tsutomu
    Ito, Katsuyoshi
    Yoshida, Koji
    Sone, Teruki
    Murakami, Koichi
    Kanki, Akihiko
    Watanabe, Shigeru
    Higashi, Hiroki
    Yamashita, Takenori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 182 - 186
  • [23] Functional evaluation of normothermic ischemia and Reperfusion injury in dog kidney by combining MR diffusion-weighted Imaging and Gd-DTPA enhanced first-pass perfusion
    Liu, AS
    Xie, JX
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (06) : 683 - 693