共 21 条
The Midterm Outcomes of Bioprosthetic Pulmonary Valve Replacement in Children
被引:22
作者:
Shinkawa, Takeshi
[1
]
Lu, Chiajung K.
[1
]
Chipman, Carl
[1
]
Tang, Xinyu
[2
]
Gossett, Jeffrey M.
[2
]
Imamura, Michiaki
[1
]
机构:
[1] Univ Arkansas Med Sci, Arkansas Childrens Hosp, Div Pediat & Congenital Cardiothorac Surg, Little Rock, AR 72205 USA
[2] Univ Arkansas Med Sci, Arkansas Childrens Hosp, Dept Pediat, Biostat Program, Little Rock, AR 72205 USA
关键词:
congenital heart disease;
CHD;
pulmonary valve;
pediatric;
D O I:
10.1053/j.semtcvs.2015.07.010
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
The purpose of this study was to assess the outcomes of bioprosthetic pulmonary valve replacement (PVR) in children. This is a retrospective review of all bioprosthetic PVR in children (≤20-year old) between 1992 and 2013 at a single institution. Most outcomes studied included pulmonary valve reintervention and bioprosthetic valve function. A total of 136 bioprosthetic PVRs were identified for 123 patients. The median age and body weight at the time of operation were 13.2 years and 48.4 kg. There were 1 early death and 3 late deaths during the median follow-up of 7.2 years (0-22.0 years). The actuarial transplant-free survival was 97.6% at 10 years. There were 43 bioprosthesis reinterventions with 29 reoperations and 14 catheter-based interventions. The freedom from bioprosthesis reintervention was 89.6% and 55.0% at 5 and 10 years, respectively. Echocardiographic bioprosthesis dysfunction (≥moderate bioprosthesis insufficiency, ≥50 mm Hg peak gradient through bioprosthesis, or bioprosthesis endocarditis with vegetation) was found in 57 bioprostheses. The freedom from bioprosthesis dysfunction was 74.0% and 32.8% at 5 and 10 years, respectively. Results from the Cox proportional hazards models showed that age had significant association with freedom from bioprosthesis reintervention and freedom from bioprosthesis dysfunction (P < 0.001 and P = 0.03), whereas bioprosthesis type had nonsignificant association with freedom from bioprosthesis dysfunction (P = 0.068). Bioprosthetic PVR in children had excellent early outcomes but rapidly deteriorating midterm outcomes. Careful and close follow-up are necessary for children with bioprosthesis in the pulmonary position. © 2015 Elsevier Inc.
引用
收藏
页码:310 / 318
页数:9