SEISMIC ANALYSIS OF LINKS OF VARIOUS LENGTHS IN ECCENTRICALLY BRACED FRAMES

被引:23
|
作者
GHOBARAH, A
RAMADAN, T
机构
[1] McMaster Univ, Hamilton, Ont
关键词
STEEL; ECCENTRIC; BRACED; FRAME; LINK; SEISMIC; DUCTILITY; DESIGN;
D O I
10.1139/l91-016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Eccentrically braced steel frames have excellent elastic stiffness under moderate lateral loads and good ductility when subjected to severe seismic loading conditions. Under extreme loading, the inelastic behaviour is designed to be confined to a ductile link element. The behaviour of links of various lengths in eccentrically braced frames is evaluated using a finite element model. The link is subjected to extreme cyclic loading simulating a severe earthquake. The effect of the link length on its performance, capacity for energy dissipation, plastic mechanisms, and mode of failure are investigated. Measures for improving the performance of long links are examined. It was found that the most efficient link is the short shear link. However, the short link deformation is characterized by large angles of deformation, which may cause substantial damage to the nonstructural elements. On the other hand, long links were found to have smaller angles of deformation than short links, but with reduced ductility levels. An effective approach to improve the performance of long links is by increasing the flange thickness of the link section with the appropriate adjustment to the stiffener design. This technique can be applied to links of length up to 1.4 times the critical shear link length.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [41] Seismic analysis and design of multi-tiered steel eccentrically braced frames with built-up tubular links
    Ashrafi, Abolfazl
    Imanpour, Ali
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2025, 190
  • [42] HYSTERESIS BEHAVIOR OF SEISMIC ISOLATORS IN EARTHQUAKES NEAR A FAULT IN ECCENTRICALLY BRACED FRAMES WITH VERTICAL AND HORIZONTAL LINKS
    Dehaki, M. Dehvari
    Azmoon, P.
    Azmoon, F.
    Seddiqpour, A.
    Dehaki, N. Dehvari
    JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2016, 8 : 1992 - 2006
  • [43] HYSTERESIS BEHAVIOR OF SEISMIC ISOLATORS IN EARTHQUAKES NEAR A FAULT IN ECCENTRICALLY BRACED FRAMES WITH VERTICAL AND HORIZONTAL LINKS
    Dehaki, M. A. Dehvari
    Azmoon, P.
    Azmoon, F.
    Seddiqpour, A.
    Dehaki, N. Dehvari
    JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2016, 8 : 152 - 166
  • [44] Seismic performance of eccentrically braced frames with short-links: IDA approach using chilean earthquakes
    Mata, Ramon
    Nunez, Eduardo
    Calo, Byron
    Herrera, Ricardo
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [45] Design and seismic response of shear critical eccentrically braced frames
    Koboevic, S
    Redwood, R
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1997, 24 (05) : 761 - 771
  • [46] Lateral Reliability Assessment of Eccentrically Braced Frames Including Horizontal and Vertical Links Under Seismic Loading
    Abdelhamid, Faycal
    Saadi, Mohamed
    Yahiaoui, Djarir
    Lahbari, Noureddine
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2022, 12 (02) : 8278 - 8283
  • [47] Seismic Yield Displacement Profile in Steel Eccentrically Braced Frames
    Zahedi, M. J.
    Saffari, H.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2019, 32 (09): : 1248 - 1259
  • [48] PRACTICAL ADVANCED ANALYSIS FOR ECCENTRICALLY BRACED FRAMES
    Hu, Shujun
    Wang, Zhan
    ADVANCED STEEL CONSTRUCTION, 2015, 11 (01): : 95 - 110
  • [49] Axial Load Effects on the Response of Yielding Links in Eccentrically Braced Frames
    Mortazavi, Pedram
    Kwon, Oh-Sung
    Christopoulos, Constantin
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2024 - VOL 1, 2024, 519 : 756 - 768
  • [50] Tubular links for eccentrically braced frames. II: Experimental verification
    Berman, Jeffrey W.
    Bruneau, Michel
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2008, 134 (05): : 702 - 712