Establishment of national diagnostic reference levels (DRLs) for radiotherapy localisation computer tomography of the head and neck

被引:7
作者
Clerkin, Celine [1 ]
Brennan, Sinead [2 ]
Mullaney, Laura M. [1 ]
机构
[1] Trinity Coll Dublin, Sch Med, Appl Radiat Therapy Trinity Res Grp, Discipline Radiat Therapy, Dublin, Ireland
[2] St Lukes Hosp, Dept Radiat Oncol, St Lukes Radiat Oncol Network, Dublin 6, Ireland
关键词
Radiotherapy; CT localisation; Diagnostic reference levels; Head and neck;
D O I
10.1016/j.rpor.2018.07.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The aim of this research is to establish if variation exists in the dose delivered for head and neck (HN) localisation computed tomography (CT) imaging in radiation therapy (RT); to propose a national diagnostic reference levels (DRLs) for this procedure and to make a comparison between the national DRL and a DRL of a European sample. Background: CT has become an indispensable tool in radiotherapy (RT) treatment planning. It is a requirement of legislation in many countries that doses of ionising radiation for medical exposures be kept As Low As Reasonably Achievable'. There are currently no dose guidelines for RT localisation CT of the HN. Materials and methods: All RT departments in Ireland and a sample of European departments were surveyed. Dose data on CT dose length product (DLP); dose index volume (CTDIvol); current time product; tube voltage and scan length was acquired for ten average-sized HN patients from each department. DRLs were proposed for DLP and CTDIvol using the rounded 75th percentile of the distribution of the means. Results: 42% of Irish departments and one European department completed the survey. Significant variation was found in the mean DLP, CTDIvol and scan lengths across the Irish departments. The proposed Irish DRL is 882 mGy cm and 21 mGy and the European department DRL is 816 mGy cm and 21 mGy, for DLP and CTDIvol, respectively. Conclusions: Variation exists in doses used for HN RT localisation CT. DRLs have been proposed for comparison purposes with the aim of dose optimisation. (C) 2018 Greater Poland Cancer Centre. Published by Elsevier Sp. z o.o. All rights reserved.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 26 条
[1]  
Amis E Stephen Jr, 2007, J Am Coll Radiol, V4, P272, DOI 10.1016/j.jacr.2007.03.002
[2]   Adult reference levels in diagnostic and interventional radiology for temporary use in Switzerland [J].
Aroua, A ;
Besançon, A ;
Buchillier-Decka, I ;
Trueb, P ;
Valley, JF ;
Verdun, FR ;
Zeller, W .
RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) :289-295
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   The 15-country collaborative study of cancer risk among radiation workers in the nuclear industry:: Estimates of radiation-related cancer risks [J].
Cardis, E. ;
Vrijheid, M. ;
Blettner, M. ;
Gilbert, E. ;
Hakama, M. ;
Hill, C. ;
Howe, G. ;
Kaldor, J. ;
Muirhead, C. R. ;
Schubauer-Berigan, M. ;
Yoshimura, T. ;
Bermann, F. ;
Cowper, G. ;
Fix, J. ;
Hacker, C. ;
Heinmiller, B. ;
Marshall, M. ;
Thierry-Chef, I. ;
Utterback, D. ;
Ahn, Y-O ;
Amoros, E. ;
Ashmore, P. ;
Auvinen, A. ;
Bae, J-M. ;
Bernar, J. ;
Biau, A. ;
Combalot, E. ;
Deboodt, P. ;
Sacristan, A. Diez ;
Eklof, M. ;
Engels, H. ;
Engholm, G. ;
Gulis, G. ;
Habib, R. R. ;
Holan, K. ;
Hyvonen, H. ;
Kerekes, A. ;
Kurtinaitis, J. ;
Malker, H. ;
Martuzzi, M. ;
Mastauskas, A. ;
Monnet, A. ;
Moser, M. ;
Pearce, M. S. ;
Richardson, D. B. ;
Rodriguez-Artalejo, F. ;
Rogel, A. ;
Tardy, H. ;
Telle-Lamberton, M. ;
Turai, I. .
RADIATION RESEARCH, 2007, 167 (04) :396-416
[5]  
Connor S.O., 2016, BRIT J RADIOL, V89
[6]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[7]   Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[8]   A review of patient dose and optimisation methods in adult and paediatric CT scanning [J].
Dougeni, E. ;
Faulkner, K. ;
Panayiotakis, G. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) :E665-E683
[9]   Establishment of CT diagnostic reference levels in Ireland [J].
Foley, S. J. ;
McEntee, M. F. ;
Rainford, L. A. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018) :1390-1397
[10]  
Friberg E G, 2008, NATL COLLECTION LOCA