Short Circuit Analysis of 500KV Hubco-Jamshoro Transmission Network and Improvement of Voltage Stability

被引:0
|
作者
Shah, Syed Asif Ali [1 ]
Larik, Abdul Sattar [1 ]
Irshad, Ahsan [1 ]
机构
[1] Mehran Univ Engn & Technol, Dept Elect Engn, Jamshoro, Pakistan
关键词
Asymmetrical and Symmetrical Faults; Transmission Network; Wind Power Plants; Fault Analysis; Voltage Stability;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, ETAP (Electrical Transient Analyzer Program) GUI (Graphical User Interface) simulation tool has been used to perform the short circuit analysis of power transmission lines. The existing 500KV Hubco-Jamshoro Transmission network of National Transmission & Dispatch Company, Pakistan has been selected to simulate the network. We provide a method for the analysis of short circuit current values for four different faults, i.e. 3-phase, line-ground, line-line and line-line-ground. It also covers the improvement of voltage stability of the network after integration with proposed projects of Jhimpir and Gharo wind power plants. The results of 3-phase and single phase line to ground faults are carried out using conventional method and to validate them these are compared with that of simulated ones. This paper also provides a way of improvement in voltage stability of Hubco-Jamshoro transmission network after adding the proposed projects of wind power plants at Jhimpir and Gharo.
引用
收藏
页码:707 / 714
页数:8
相关论文
共 50 条
  • [1] Analysis on the Electromagnetic Environmental Factors of 500kV Double Circuit Transmission Line
    Qi, Jianzhao
    Li, Jingyi
    ADVANCES IN ENVIRONMENTAL ENGINEERING, 2012, 599 : 884 - 887
  • [2] Analysis of Fault Recorder Data for Short-Circuit Current in a 500kV Busbar Short-Circuit Accident
    Cao, Wei
    Wang, Yong-sheng
    Liu, Bei
    Wang, Wei
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 1290 - +
  • [3] Phase Arrangement for 500kV Quadruple Circuit Transmission Line in Indonesia
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung S.
    2016 INTERNATIONAL CONFERENCE ON SMART GREEN TECHNOLOGY IN ELECTRICAL AND INFORMATION SYSTEMS (ICSGTEIS), 2016, : 33 - 37
  • [4] Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines
    Lu, Hailiang
    Wen, Xishan
    Zhang, Chengwei
    Tong, Xuefang
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3535 - +
  • [5] Research on Short-circuit Test of 500kV Hybrid HVDC Circuit Breaker
    Zhao Shu-zhen
    Zhang Jin-xiang
    Li Zhen-dong
    Yu Wen-bo
    Wang Yu-qiang
    Niu Xue-fei
    Kan Shi-yang
    2017 INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA), 2017, : 126 - 130
  • [6] Analysis and Improvement Plan for Mismatch of Remote Tripping Circuit in 500kV Line Relay Protection
    Liu, Yuwen
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 426 - 430
  • [7] Analysis of 500kV Capacitive Voltage Transformer Leakage Fault
    Yu Bing
    Zhao Lin
    Lin Haofan
    Zhou Luyao
    Yang Zhi
    Liu Shuang
    2021 THE 6TH INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM 2021), 2021, : 403 - 407
  • [8] The Anomaly Power Transmission and Analysis at a 500kV GIS Substation
    Qi Geqing
    Wu Gang
    Qi Zhuang
    Meng Fanlong
    Jin Daxin
    Zhang Wei
    Zhang Nan
    Wang Lulu
    4TH INTERNATIONAL CONFERENCE ON MECHANICS AND MECHATRONICS RESEARCH (ICMMR 2017), 2017, 224
  • [9] Research on Improving 220kV Bus Short Circuit Current Level of 500kV Substation
    Wang, Kui
    Yan, Dawei
    Li, Hui
    Wang, Xuejun
    Li, Yuanyuan
    Luo, Tao
    Lei, Zheng
    Cui, Guangsheng
    Zhou, Jin
    Liu, Lixia
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 1706 - 1710
  • [10] Research on Eliminating Closing Resistors in 500kV and above Transmission lines circuit Breakers
    Tian Shu
    Guo Peng-jun
    He Jin-peng
    ELECTRICAL INFORMATION AND MECHATRONICS AND APPLICATIONS, PTS 1 AND 2, 2012, 143-144 : 3 - 7