Aortic valve replacement using stentless bioprostheses. Surgical principles and step-by-step operational instructions using the Freestyle prosthesis as an example

被引:0
作者
Albert, A. [1 ]
Ennker, J. [2 ]
机构
[1] Univ Klinikum Dusseldorf, Abt Kardiovaskulare Chirurg, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] MediClin Herzzentrum Lahr Baden, Herz Thorax & Gefasschirurg, Lahr, Germany
来源
ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE | 2010年 / 24卷 / 03期
关键词
Aortic valve replacement; Stentless bioprosthesis; Hemodynamic; Continuous medical education; Quality assurance;
D O I
10.1007/s00398-010-0774-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stentless valves were designed to improve postoperative hemodynamics in comparison to stented bioprosthesis. The implantation technique of stentless valves is very different from conventional bioprostheses: a stented bioprosthesis maintains its form, due to the rigid stent, whereas the form of a stentless valve depends on the surgical suture lines. The general goal is to snugly fit a stentless valve into the aortic root and, thereby, to ensure optimal hemodynamic results. Insufficient coaptation of the cusps and bulging of the prosthesis into the outflow tract are the results of suboptimal implantation techniques. Residual gradients after stentless valve implantation impede postoperative quality of life and long-term survival. The present paper aims to describe the principles of implantation of stentless valves and to standardize the procedure using the Freestyle prosthesis as an example. The standardization of surgical technique and the identification of common pitfalls are mandatory to avoid unfavorable learning curves and to improve quality of life and long-term survival.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 23 条
[1]   Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle® stentless bioprosthesis and its consequences: A follow-up study in 587 patients [J].
Albert, Alexander ;
Florath, Ines ;
Rosendahl, Ulrich ;
Hassanein, Wael ;
Hodenberg, Eberhard V. ;
Bauer, Stefan ;
Ennker, Ina ;
Ennker, Juergen .
JOURNAL OF CARDIOTHORACIC SURGERY, 2007, 2 (1)
[2]  
Albert A, 2010, J HEART VALVE DIS, V19, P104
[3]  
Bach D S, 2001, Semin Thorac Cardiovasc Surg, V13, P75
[4]   Impact of implant technique following freestyle stentless aortic valve replacement [J].
Bach, DS ;
Cartier, PC ;
Kon, ND ;
Johnson, KG ;
Deeb, GM ;
Doty, DB .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1107-1113
[5]  
Barratt-Boyes BG, 1992, EUR J CARDIO-THORAC, P39
[6]  
Doty JR, 1998, J CARDIAC SURG, V13, P208
[7]   Learning how and learning what: Effects of tacit and codified knowledge on performance improvement following technology adoption [J].
Edmondson, AC ;
Winslow, AB ;
Bohmer, RMJ ;
Pisano, GP .
DECISION SCIENCES, 2003, 34 (02) :197-223
[8]   Choice of prosthetic heart valve in today's practice [J].
El Oakley, Reida ;
Kleine, Peter ;
Bach, David S. .
CIRCULATION, 2008, 117 (02) :253-256
[9]  
Ennker J, 2006, J CARDIOVASC SURG, V21, P1
[10]   Ten-year experience with stentless aortic valves: Full-root versus subcoronary implantation [J].
Ennker, Juergen A. C. ;
Albert, Alexander A. ;
Rosendahl, Ulrich P. ;
Ennker, Ina C. ;
Dalladaku, Fatmir ;
Florath, Ines .
ANNALS OF THORACIC SURGERY, 2008, 85 (02) :445-453