The L3 forward muon detector

被引:0
|
作者
Viertel, GM
机构
[1] ETH, Zurich
关键词
D O I
10.1016/0168-9002(95)00748-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An array of 96 large drift chambers combined with resistive plate chambers for triggering purposes is described. The system extends the acceptance for the muon detection in the L3 experiment at LEP from 62% to 92% of the solid angle. Special features of the system are: economical design, a robust multi-cell structure, short construction time, self-calibrating drift chambers, multiplexed readout and a single wire resolution of about 250 mu m. The installation of the full system has been completed during LEP shutdown 1994/1995.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 50 条
  • [1] The forward muon detector of L3
    Adam, A
    AguilarBenitez, M
    Alarcon, J
    Alberdi, J
    Alexandrov, V
    Aloisio, A
    Alviggi, MG
    Anderhub, H
    Ariza, M
    Azemoon, T
    Aziz, T
    Bakker, F
    Banerjee, S
    Banicz, K
    Barcala, J
    Becker, U
    Berdugo, J
    Berges, P
    Betev, BL
    Biland, A
    Bobbink, GJ
    Bock, R
    Bohm, A
    Borissov, V
    Bosseler, K
    Bouvier, P
    Brambilla, E
    Burger, JD
    Burgos, C
    Buskens, J
    Carlier, JC
    Carlino, G
    Casaus, J
    Cavallo, N
    Cerjak, I
    Cerrada, M
    Chang, YH
    Chen, HS
    Chendvankar, SR
    Chvatchkine, V
    Daniel, M
    deAsmundis, R
    Decreuse, G
    Deiters, K
    Djambazov, L
    Duraffourg, P
    Erne, FC
    Esser, H
    Ezekiev, S
    Faber, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (2-3): : 342 - 366
  • [2] L3 forward muon detector
    Viertel, G.M.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 367 (1-3):
  • [3] The new forward muon detector of L3: Features and implementation
    Becker, UJ
    NUCLEAR PHYSICS B, 1995, : 455 - 460
  • [4] THE MUON FILTER OF THE L3 DETECTOR
    ADRIANI, O
    BOCCIOLINI, M
    CARTACCI, AM
    CIVININI, C
    DALESSANDRO, R
    GALLO, E
    LANDI, G
    MARCHIONNI, A
    MESCHINI, M
    MONTELEONI, B
    PIERI, M
    SPILLANTINI, P
    WANG, YF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (03): : 493 - 500
  • [5] TEST-RESULTS OF THE L3 PRECISION MUON DETECTOR
    ADEVA, B
    AGUILARBENITEZ, M
    ALOISIO, A
    ALVIGGI, MG
    ANTREASYAN, D
    BAKSAY, L
    BECKER, U
    BERDUGO, J
    BOBBINK, GJ
    BRANSON, JG
    BURGOS, C
    BURGER, JD
    CAMPANA, D
    CARBONARA, F
    CERRADA, M
    CHANG, YH
    CHEN, ML
    CHIEFARI, G
    COLINO, N
    DRAGO, E
    DUINKER, P
    DURAN, I
    ERNE, F
    FABBRETTI, R
    FABRE, M
    FEHER, S
    GAU, SS
    GETTNER, M
    GONZALEZ, E
    VANDERGRAAF, H
    GUSEWELL, D
    HARTJES, FG
    INNOCENTE, V
    JIN, BN
    KONIG, A
    LANZANO, S
    LEGOFF, JM
    LEIJTENS, X
    LI, L
    LOKOS, S
    MANA, C
    MARTINEZ, L
    MASSARO, GGG
    MAO, YF
    MAGAHIZ, R
    MCBRIDE, P
    MEROLA, L
    NAPOLITANO, M
    ONVLEE, H
    PATERNOSTER, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (03): : 335 - 341
  • [6] THE L3 FORWARD-BACKWARD MUON RPC TRIGGER SYSTEM
    ALOISIO, A
    ALVIGGI, MG
    CARLINO, G
    CAVALLO, N
    DEASMUNDIS, R
    INNOCENTE, V
    LANZANO, S
    LISTA, L
    PAOLUCCI, P
    PICCOLO, D
    PATRICELLI, S
    SCIACCA, C
    SOULIMOV, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (1-2): : 340 - 344
  • [7] The alignment of the L3 forward-backward muon chambers at LEP200
    Berdugo, J
    Burgos, C
    Cerrada, M
    Deiters, K
    Fabre, M
    Lustermann, W
    Robohm, A
    VanRossum, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 384 (2-3): : 364 - 370
  • [8] Performances of the RPC trigger system of the L3 forward-backward muon spectrometer
    Aloisio, A
    Alviggi, MG
    Carlino, G
    Cavallo, N
    deAsmundis, R
    Innocente, V
    Lanzano, S
    Lista, L
    Paolucci, P
    Patricelli, S
    Piccolo, D
    Sciacca, C
    Soulimov, V
    NUCLEAR PHYSICS B, 1995, : 417 - 422
  • [9] PHYSICS WITH THE L3 DETECTOR
    TING, SCC
    SUPPLEMENT OF THE PROGRESS OF THEORETICAL PHYSICS, 1985, (85): : 75 - 103
  • [10] MUON DETECTION IN THE L3 EXPERIMENT AT LEP
    ADEVA, B
    AGUILARBENITEZ, M
    ANTREASYAN, D
    BECKER, U
    BERDUGO, J
    BOBBINK, GJ
    BRANSON, J
    BURGER, J
    BURGOS, C
    CAMPANA, D
    CARBONARA, F
    CERRADA, M
    CHANG, YH
    CHEN, ML
    CHIEFARI, G
    DRAGO, E
    DUINKER, P
    DURAN, I
    ERNE, FC
    FABBRETTI, R
    FABRE, M
    GAU, SS
    GETTNER, M
    GONZALEZ, E
    VANDERGRAAF, H
    HARTJES, FG
    INNOCENTE, V
    KONIG, AC
    LANZANO, S
    LEGOFF, JM
    LI, L
    MANA, C
    MARTINEZLASO, L
    MASSARO, GGG
    MCBRIDE, P
    MEROLA, L
    NAPOLITANO, M
    ONVLEE, J
    PATERNOSTER, G
    PATRICELLI, S
    PENG, Y
    PROKOFIEV, O
    QIAN, JM
    RAZIS, P
    ROMERO, L
    RUBIO, JA
    RYKACZEWSKI, H
    SALICIO, J
    SCHETKOWSKI, A
    SCHMITT, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (01): : 187 - 193