AUTOMATED-ANALYSIS OF URINARY CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ON-LINE-SAMPLE PRETREATMENT

被引:27
|
作者
PASTORIS, A
CERUTTI, L
SACCO, R
DEVECCHI, L
SBAFFI, A
机构
[1] Laboratorio Analisi, Ospedale SS. Trinità, 28021 Borgomanero
来源
关键词
D O I
10.1016/0378-4347(94)00490-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and automated solid-phase extraction for the selective and quantitative HPLC analysis of free catecholamines in urine is described. The urinary catecholamines react with diphenylboric acid, giving a complex at pH 8.5 which is strongly retained on a PLRP-S cartridge; elution is accomplished with the same mobile phase used for HPLC analysis. Separation is performed by ion-pair reversed-phase HPLC, with sodium heptanesulphate as counter-ion, and a totally end-capped C-18 analytical column. Quantitation is achieved with an electrochemical detector. A Spark Holland Prospekt system controls the on-line solid-phase extraction, preconcentration and direct elution to the LC column. Chromatography run-time is 10 min and the total time to process one urine sample is ca. 12 min.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 50 条
  • [41] CONVENIENT, IN-LINE PURIFICATION OF SACCHARIDE MIXTURES IN AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FITT, LE
    JOURNAL OF CHROMATOGRAPHY, 1978, 152 (01): : 243 - 246
  • [42] ESTIMATION OF CATECHOLAMINES IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    KISSINGER, PT
    RIGGIN, RM
    ALCORN, RL
    RAU, LD
    BIOCHEMICAL MEDICINE, 1975, 13 (04): : 299 - 306
  • [43] SEPARATION AND DETECTION OF SMALL AMOUNTS OF CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OKAMOTO, KI
    ISHIDA, Y
    ASAI, K
    JOURNAL OF CHROMATOGRAPHY, 1978, 167 (DEC): : 205 - 217
  • [44] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF CATECHOLAMINES AND THEIR CONGENERS
    ASMUS, PA
    FREED, CR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (SEP): : 40 - 40
  • [45] SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SYSTEM WITH FLUOROMETRIC DETECTION OF 3 URINARY CATECHOLAMINES IN THE SAME RANGE
    MORI, K
    IMAI, K
    ANALYTICAL BIOCHEMISTRY, 1985, 146 (02) : 283 - 286
  • [46] SEPARATION OF CATECHOLAMINES AND THEIR METABOLITES (16 COMPOUNDS) USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - APPLICATION TO URINARY DETERMINATIONS
    CUISINAUD, G
    BERNARD, N
    JULIEN, C
    RODRIGUEZ, C
    SASSARD, J
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1983, 76 (09): : 1097 - 1097
  • [47] Rifampicin Interference in the Measurement of Urinary Catecholamines by High-Performance Liquid Chromatography
    Kim, Hyun-Ki
    Ko, Dae-Hyun
    Jeong, Tae-Dong
    Lee, Sang-Hee
    Lee, Woochang
    Lee, Soo-Youn
    Chun, Sail
    Song, Junghan
    Min, Won-Ki
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2015, 45 (03): : 356 - 359
  • [48] LIQUID SAMPLE LOOP GEOMETRY FOR TRACE ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH LARGE SAMPLE VOLUMES
    ZEHNER, JM
    SIMONAITIS, RA
    ANALYTICAL CHEMISTRY, 1978, 50 (07) : 1013 - 1014
  • [49] COUPLING OF DIALYSIS WITH LIQUID-CHROMATOGRAPHY FOR AUTOMATED-ANALYSIS OF COMPLEX SAMPLES
    VERILLON, F
    QIAN, F
    ANALUSIS, 1991, 19 (09) : 271 - 277
  • [50] ANALYSIS OF INOSITOL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WANG, WT
    SAFAR, JR
    ZOPF, D
    ANALYTICAL BIOCHEMISTRY, 1990, 188 (02) : 432 - 435