AUTOMATED-ANALYSIS OF URINARY CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ON-LINE-SAMPLE PRETREATMENT

被引:27
|
作者
PASTORIS, A
CERUTTI, L
SACCO, R
DEVECCHI, L
SBAFFI, A
机构
[1] Laboratorio Analisi, Ospedale SS. Trinità, 28021 Borgomanero
来源
关键词
D O I
10.1016/0378-4347(94)00490-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and automated solid-phase extraction for the selective and quantitative HPLC analysis of free catecholamines in urine is described. The urinary catecholamines react with diphenylboric acid, giving a complex at pH 8.5 which is strongly retained on a PLRP-S cartridge; elution is accomplished with the same mobile phase used for HPLC analysis. Separation is performed by ion-pair reversed-phase HPLC, with sodium heptanesulphate as counter-ion, and a totally end-capped C-18 analytical column. Quantitation is achieved with an electrochemical detector. A Spark Holland Prospekt system controls the on-line solid-phase extraction, preconcentration and direct elution to the LC column. Chromatography run-time is 10 min and the total time to process one urine sample is ca. 12 min.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 50 条
  • [1] AUTOMATED-ANALYSIS OF MITOMYCIN-C IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE SAMPLE PRETREATMENT
    TJADEN, UR
    DEBRUIJN, EA
    VANDERHOEVEN, RAM
    JOL, C
    VANDERGREEF, J
    LINGEMAN, H
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 420 (01): : 53 - 62
  • [2] ANALYSIS OF URINARY CATECHOLAMINES AND METABOLITES WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION
    MOLEMAN, P
    BORSTROK, JJM
    BIOGENIC AMINES, 1985, 3 (01) : 33 - 71
  • [3] ANALYSIS OF URINARY CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY IN THE PRESENCE OF LABETALOL METABOLITES
    BINDER, SR
    BIAGGI, ME
    JOURNAL OF CHROMATOGRAPHY, 1987, 385 : 241 - 247
  • [5] AUTOMATED-ANALYSIS OF ANTIEPILEPTIC DRUGS IN SERUM BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NAZARETH, A
    JARAMILLO, L
    KARGER, BL
    GIESE, RW
    SNYDER, LR
    JOURNAL OF CHROMATOGRAPHY, 1984, 309 (02): : 357 - 368
  • [6] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MEAKIN, G
    ALLINGTON, R
    AMERICAN LABORATORY, 1980, 12 (08) : 65 - &
  • [7] ANALYSIS OF URINARY PROTEINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ORTI, DL
    HILL, RH
    NEEDHAM, LL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 159 - ANYL
  • [8] COMPARATIVE-STUDY OF URINARY CATECHOLAMINES BY FLUORIMETRY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FERRIERE, C
    FUNES, A
    BARBIER, C
    ANNALES DE BIOLOGIE CLINIQUE, 1982, 40 (04) : 452 - 453
  • [9] DETERMINATION OF FREE URINARY CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    VOLIN, P
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 655 (01): : 121 - 126
  • [10] 2 SYSTEMS FOR THE AUTOMATED-ANALYSIS OF DRUGS IN BIOLOGICAL-FLUIDS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DOYLE, E
    MCDOWALL, RD
    MURKITT, GS
    PICOT, VS
    ROGERS, SJ
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (01): : 67 - 77