COMPUTERIZED PATIENT ANESTHESIA RECORDS - LESS TIME AND BETTER QUALITY THAN MANUALLY PRODUCED ANESTHESIA RECORDS

被引:65
作者
EDSALL, DW
DESHANE, P
GILES, C
DICK, D
SLOAN, B
FARROW, J
机构
[1] Department of Anesthesiology, Burbank Hospital, Fitchburg, MA
关键词
MEDICAL RECORDS; COMPUTERIZED; QUALITY CONTROL; TASK ANALYSIS;
D O I
10.1016/0952-8180(93)90118-X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To compare manual and computerized anesthesia information management systems (AIMS's) with respect to time demands on the anesthetist and record quality. Design: Videotaped clinical anesthesia cases were independently reviewed along with the records produced. Setting: Private practice anesthesia at a 150-bed community hospital. Patients: Ten consecutive As physical status I patients having video arthroscopy of the knee by the same surgeon and having general anesthesia. Interventions: One anesthetist recorded six cases: three with the computer and three manually. Two more anesthetists each recorded two cases: one with the computer and one manually. Measurements and Main Results: The proportion of the anesthetist's time spent on the documentation for the computer records was significantly less than that spent on manual records (14.9% vs. 36.6%; p < 0.001). Nevertheless, significantly more vital sign data points were recorded on the computer than on the manual records (245.2 vs. 45.0 vital sign points per case; p < 0.001), as well as significantly more notes and drug information (61.0 vs. 40.0 notes per case; p < 0.02). The computer record was always legible, but this was not the case with the manual records. There was no significant difference in the number of artifacts detected on the records. Conclusion: The concern that the introduction of computerized AIMS's may complicate the anesthesia working environment by requiring more time than manual AIMS's and thus detracting from direct patient care is not supported by this study. In fact, this computer approach not only required less time but also produced a more complete and higher-quality record than did the manual AIMS.
引用
收藏
页码:275 / 283
页数:9
相关论文
共 11 条
  • [1] Kennedy, Feingold, Wiener, Hosek, Analysis of tasks and human factors in anesthesia for coronary-artery bypass, Anesth Analg, 55, pp. 374-377, (1976)
  • [2] McDonald, Dzwonczyk, A time and motion study of the anaesthetist's intraoperative time, Br Anaesth, 61, pp. 738-742, (1988)
  • [3] Boquet, Bushman, Davenport, The anaesthetic machine-a study of function and design, Br J Anaesth, 52, pp. 61-67, (1980)
  • [4] Cook, McDonald, Nunziata, Differences between handwritten and automatic blood pressure records, Anesthesiology, 71, pp. 385-390, (1989)
  • [5] Zollinger, Kreul, Schneider, Man-made versus computer-generated anesthesia records, J Surg Res, 22, pp. 419-424, (1977)
  • [6] Shibutani, Ogawa, Oka, Et al., Inaccuracy of arterial pressure and heart rate in the anesthesia record a study of human factors [Abstract], Anesthesia & Analgesia, 70, (1990)
  • [7] Block, Minic, McDonald, Comparison of manual and automatic charting with a commercially available automatic anesthesia record keeper [Abstract], Anesthesiology, 73, (1990)
  • [8] Block, Normal fluctuation of physiologic cardiovascular variables during anesthesia and the phenomenon of “smoothing”, J Clin Monit, 7, pp. 141-145, (1991)
  • [9] Lerou, Dirksen, van Daele, Nijhuis, Crul, Automated charting of physiological variables in anesthesia: a quantitative comparison of automated versus handwritten anesthesia records, J Clin Monit, 4, pp. 37-47, (1988)
  • [10] Edsall, Giles, The 5-Step Burbank Certification Process, ARKIVE Patient Information Management System Manual, (1990)