A DEPTH-ENCODED PET DETECTOR

被引:38
作者
BARTZAKOS, P [1 ]
THOMPSON, CJ [1 ]
机构
[1] MCGILL UNIV,MED PHYS UNIT,MONTREAL H3A 2B4,QUEBEC,CANADA
关键词
D O I
10.1109/23.289382
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radial blurring in high-resolution positron emission tomography (PET) can be reduced by measuring the PET photon's depth of interaction within a detector crystal. Simulations show that dividing the crystal into two equiprobable regions of interaction almost eliminates this blurring. This has been done using a black band placed around a 3 cm BGO crystal, 1 cm from the front. A PMT collects light from the rear of the crystal for energy and timing measurement. Another PMT collects light through a light guide from the top-front of the crystal to find the depth of interaction. Gamma rays interacting in the front of the crystal produce a strong, signal in the depth-sensing PMT, while interactions behind the band produce weaker (< 10%) signal. The intensity of the light recorded by the energy PMT is almost constant (within +/- 3%) for interactions at any depth in the crystal.
引用
收藏
页码:732 / 738
页数:7
相关论文
共 15 条
  • [1] DESIGN OF A HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPH USING SOLID-STATE SCINTILLATION DETECTORS
    CARRIER, C
    MARTEL, C
    SCHMITT, D
    LECOMTE, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 685 - 690
  • [2] A STUDY OF THE POSSIBILITY OF USING MULTI-SLICE PET SYSTEMS FOR 3D IMAGING
    DAHLBOM, M
    ERIKSSON, L
    ROSENQVIST, G
    BOHM, C
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1066 - 1071
  • [3] INITIAL CHARACTERIZATION OF A BGO-PHOTODIODE DETECTOR FOR HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY
    DERENZO, SE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 620 - 626
  • [4] INITIAL CHARACTERIZATION OF A POSITION-SENSITIVE PHOTODIODE BGO DETECTOR FOR PET
    DERENZO, SE
    MOSES, WW
    JACKSON, HG
    TURKO, BT
    CAHOON, JL
    GEYER, AB
    VULETICH, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1084 - 1089
  • [5] A POSITRON TOMOGRAPH WITH 600-BGO CRYSTALS AND 2.6 MM RESOLUTION
    DERENZO, SE
    HUESMAN, RH
    CAHOON, JL
    GEYER, AB
    MOSES, WW
    UBER, DC
    VULETICH, T
    BUDINGER, TF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 659 - 664
  • [6] EVANS A, UNPUB IEEE T MED IMA
  • [8] KELLER N, 1983, IEEE T NUCL SCI, V30, P556
  • [9] ON THE USE OF TAPERED BISMUTH-GERMANATE CRYSTALS IN POSITRON EMISSION TOMOGRAPHY
    LUPTON, LR
    KELLER, NA
    THOMPSON, CJ
    ANDERSON, LL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (02) : 361 - 368
  • [10] EFFECTS OF DETECTOR WOBBLE MOTION ON IMAGE NOISE IN POSITRON EMISSION TOMOGRAPHY
    PALMER, MR
    BERGSTROM, M
    BEDDOES, MP
    PATE, BD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (01) : 58 - 62