A DEPTH-ENCODED PET DETECTOR

被引:38
作者
BARTZAKOS, P [1 ]
THOMPSON, CJ [1 ]
机构
[1] MCGILL UNIV,MED PHYS UNIT,MONTREAL H3A 2B4,QUEBEC,CANADA
关键词
D O I
10.1109/23.289382
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radial blurring in high-resolution positron emission tomography (PET) can be reduced by measuring the PET photon's depth of interaction within a detector crystal. Simulations show that dividing the crystal into two equiprobable regions of interaction almost eliminates this blurring. This has been done using a black band placed around a 3 cm BGO crystal, 1 cm from the front. A PMT collects light from the rear of the crystal for energy and timing measurement. Another PMT collects light through a light guide from the top-front of the crystal to find the depth of interaction. Gamma rays interacting in the front of the crystal produce a strong, signal in the depth-sensing PMT, while interactions behind the band produce weaker (< 10%) signal. The intensity of the light recorded by the energy PMT is almost constant (within +/- 3%) for interactions at any depth in the crystal.
引用
收藏
页码:732 / 738
页数:7
相关论文
共 15 条
[1]   DESIGN OF A HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPH USING SOLID-STATE SCINTILLATION DETECTORS [J].
CARRIER, C ;
MARTEL, C ;
SCHMITT, D ;
LECOMTE, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :685-690
[2]   A STUDY OF THE POSSIBILITY OF USING MULTI-SLICE PET SYSTEMS FOR 3D IMAGING [J].
DAHLBOM, M ;
ERIKSSON, L ;
ROSENQVIST, G ;
BOHM, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1066-1071
[3]   INITIAL CHARACTERIZATION OF A BGO-PHOTODIODE DETECTOR FOR HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY [J].
DERENZO, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :620-626
[4]   INITIAL CHARACTERIZATION OF A POSITION-SENSITIVE PHOTODIODE BGO DETECTOR FOR PET [J].
DERENZO, SE ;
MOSES, WW ;
JACKSON, HG ;
TURKO, BT ;
CAHOON, JL ;
GEYER, AB ;
VULETICH, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1084-1089
[5]   A POSITRON TOMOGRAPH WITH 600-BGO CRYSTALS AND 2.6 MM RESOLUTION [J].
DERENZO, SE ;
HUESMAN, RH ;
CAHOON, JL ;
GEYER, AB ;
MOSES, WW ;
UBER, DC ;
VULETICH, T ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :659-664
[6]  
EVANS A, UNPUB IEEE T MED IMA
[8]  
KELLER N, 1983, IEEE T NUCL SCI, V30, P556
[9]   ON THE USE OF TAPERED BISMUTH-GERMANATE CRYSTALS IN POSITRON EMISSION TOMOGRAPHY [J].
LUPTON, LR ;
KELLER, NA ;
THOMPSON, CJ ;
ANDERSON, LL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (02) :361-368
[10]   EFFECTS OF DETECTOR WOBBLE MOTION ON IMAGE NOISE IN POSITRON EMISSION TOMOGRAPHY [J].
PALMER, MR ;
BERGSTROM, M ;
BEDDOES, MP ;
PATE, BD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1985, 4 (01) :58-62