Accuracy and reliability of stitched cone-beam computed tomography images

被引:14
|
作者
Egbert, Nicholas [1 ]
Cagna, David R. [2 ]
Ahuja, Swati [2 ]
Wicks, Russell A. [2 ]
机构
[1] Reconstruct Dent Specialists Utah, Salt Lake City, UT USA
[2] Univ Tennessee, Hlth Sci Ctr, Coll Dent, Dept Prosthodont, Memphis, TN 38163 USA
关键词
Cone-Beam Computed Tomography; Computer-Aided Design; Dental Implants;
D O I
10.5624/isd.2015.45.1.41
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [41] Reliability and accuracy of assessing temporary anchorage device-tooth root contact with cone-beam computed tomography
    Srinivasan, Soorya
    Tee, Boon Ching
    Wang, Amy
    Gohel, Anita
    Kim, Do-Gyoon
    Deguchi, Toru
    Sun, Zongyang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2021, 159 (03) : 271 - 280
  • [42] Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations
    Leung, Cynthia C.
    Palomo, Leena
    Griffith, Richard
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S109 - S119
  • [43] Accuracy of measurements of mandibular anatomy in cone beam computed tomography images
    Ludlow, John B.
    Laster, William Stewart
    See, Meit
    Bailey, L'Tanya J.
    Garland Hershey, H.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (04): : 534 - 542
  • [44] Accuracy of cone-beam computed tomography in detecting alveolar bone dehiscences and fenestrations
    Sun, Liangyan
    Zhang, Lina
    Shen, Guofang
    Wang, Bo
    Fang, Bing
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (03) : 313 - 323
  • [45] A Phantom Study on Target Localization Accuracy Using Cone-Beam Computed Tomography
    Yan, Hui
    Zhang, Liwei
    Yin, Fang-Fang
    CLINICAL MEDICINE INSIGHTS-ONCOLOGY, 2008, 2 : 501 - 510
  • [46] The accuracy of cone-beam computed tomography in assessing maxillary molar furcation involvement
    Qiao, Jing
    Wang, Shiying
    Duan, Jinyu
    Zhang, Yong
    Qiu, Yun
    Sun, Changzhou
    Liu, Denggao
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2014, 41 (03) : 269 - 274
  • [47] Accuracy of Cone-beam Computed Tomography and Periapical Radiography in Apical Periodontitis Diagnosis
    Lopez, Fernanda Ullmann
    Poli Kopper, Patricia Maria
    Cucco, Carolina
    Bona, Alvaro Della
    Poli de Figueiredo, Jose Antonio
    Vier-Pelisser, Fabiana Vieira
    JOURNAL OF ENDODONTICS, 2014, 40 (12) : 2057 - 2060
  • [48] Accuracy of Assessing the Mandibular Canal on Cone-Beam Computed Tomography: A Validation Study
    Gerlach, Nicolaas Lucius
    Ghaeminia, Hossein
    Bronkhorst, Ewald Maria
    Berge, Stefaan Jozef
    Meijer, Gerrit Jacobus
    Maal, Thomas Jan Jaap
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 72 (04) : 666 - 671
  • [49] Evaluation of the Dosimetric Accuracy of Stereotactic Radiosurgery with Cone-Beam Computed Tomography Localization
    Tseng, T.
    Chang, Z.
    Yin, F.
    Wang, Z.
    MEDICAL PHYSICS, 2012, 39 (06) : 3659 - 3659
  • [50] Factors affecting the accuracy of buccal alveolar bone height measurements from cone-beam computed tomography images
    Wood, Ryan
    Sun, Zongyang
    Chaudhry, Jahanzeb
    Tee, Boon Ching
    Kim, Do-Gyoon
    Leblebicioglu, Binnaz
    England, Greg
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (03) : 353 - 363