Haemogobin Estimation by Non-cyanide Methods

被引:0
作者
Chakravarthy, V. Kalyan [1 ]
Chandra, D. Naveen [1 ]
Prasanna, B. Santhoshi [1 ]
Rao, T. Jaya Mastan [1 ]
Rao, D. Ranga [1 ]
机构
[1] Dr Pinnamaneni Inst Med Sci & Res Fdn, Gannavaram, India
关键词
Haemoglobincyanide; Cetrimide; Sodium Lauryl Sulphate;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Haemoglobin is an oxygen carrying protein in the red blood cells. It is estimated by the haemoglobincyanide method (HiCN). This method is known to be hazardous to the environment and occasionally harmful to the laboratory personnel also. Aims and Objectives: To compare and study the haemoglobin concentrations which were estimated by cyanide and noncyanide methods. To suggest the advantages of the cyanide free methods over the cyanide methods. To assess whether these methods were better as compared to the haemoglobincyanide method, for medical teaching, blood bank camps and for laboratory investigations. Materials and Methods: 2000 samples in which haemoglobin estimation was done by the haemoglobincyanide method, the Sodium Lauryl Sulphate method and a modified alkaline haematin method which used cetrimide were compared and statistically analyzed by using Pearson's correlation coefficient. Results: The haemoglobin concentrations which were estimated by the Sodium Lauryl Sulphate method and the modified alkaline haematin method were similar to those which were obtained by the conventional cyanmethaemoglobin method, with r=0.986 and r=0.996 respectively. Conclusion: The modified alkaline haematin method was as accurate as the cyanmethaemoglobin method. It was economical. The toxic effects of cyanide can be prevented by using this method commercially.
引用
收藏
页码:955 / 958
页数:4
相关论文
共 11 条
[1]   Validation of hemoglobin estimation using hemocue [J].
P. Bhaskaram ;
N. Balakrishna ;
K. V. Radhakrishna ;
Kamala Krishnaswamy .
The Indian Journal of Pediatrics, 2003, 70 (1) :25-28
[2]  
Bull BS, 1966, BR J PREV SOC MED, V20, P172
[3]   A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentrates [J].
Cookson, P ;
Sutherland, J ;
Cardigan, R .
VOX SANGUINIS, 2004, 87 (04) :264-271
[4]  
Kristin Bruce, 2006, J EXP BIOL, V209, P1791
[5]  
Kuttner Theodore, 1916, JAMA-J AM MED ASSOC, V16, P1370
[6]  
LEMA OE, 1994, B WORLD HEALTH ORGAN, V72, P937
[7]  
LEWIS SM, 1991, CLIN LAB HAEMATOL, V13, P279
[8]  
Moharram N. M. M., 2006, Eastern Mediterranean Health Journal, V12, P722
[9]   Evaluation of non cyanide methods for hemoglobin estimation [J].
Shah, Vinaya B. ;
Shah, Bipin S. ;
Puranik, G. V. .
INDIAN JOURNAL OF PATHOLOGY AND MICROBIOLOGY, 2011, 54 (04) :764-768
[10]   AUTOMATED CYANIDE-FREE METHOD FOR HEMOGLOBIN DETERMINATION ON TECHNICON-H.1 [J].
THEODORSEN, L .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (06) :643-648