FIELD DETECTION OF ORGANOCHLORINE PESTICIDES BY THERMAL-DESORPTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:14
作者
ROBBAT, A
LIU, CJ
LIU, TY
机构
[1] Trace Analytical Measurement Laboratory, Department of Chemistry, Tufts University, Medford
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 625卷 / 02期
关键词
D O I
10.1016/0021-9673(92)85212-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermal desorption gas chromatography-mass spectrometry (TDGC-MS) was evaluated for field detection of organochlorine pesticides in soil/sediment and water. Rapid, 3 min/sample, TDGC-MS selected ion monitoring (SIM) yielded detection limits of 50 ng/g and 40 ng/l pesticide in soil (2 g) and water (500 ml), respectively, with measurement precision <40%. MS total ion current-selected ion extraction (TIC-SIE) measurements yielded somewhat higher detection limits with measurement precision < 20%. Examples of selective pesticide detection in the presence of a wide variety of environmental contaminants in soils, pond and sea waters are provided.
引用
收藏
页码:277 / 288
页数:12
相关论文
共 17 条
[1]   MULTILABORATORY STUDY OF AUTOMATED DETERMINATIONS OF POLYCHLORINATED-BIPHENYLS AND CHLORINATED PESTICIDES IN WATER, SOIL, AND SEDIMENT BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
ALFORDSTEVENS, AL ;
EICHELBERGER, JW ;
BUDDE, WL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (03) :304-312
[2]   ANALYZING PCBS [J].
ALFORDSTEVENS, AL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (12) :1194-1199
[3]   ACCURACY AND PRECISION OF DETERMINATIONS OF CHLORINATED PESTICIDES AND POLYCHLORINATED-BIPHENYLS WITH AUTOMATED INTERPRETATION OF MASS-SPECTROMETRIC DATA [J].
ALFORDSTEVENS, AL ;
BELLAR, TA ;
EICHELBERGER, JW ;
BUDDE, WL .
ANALYTICAL CHEMISTRY, 1986, 58 (09) :2022-2029
[4]   INTERLABORATORY STUDY ON DETERMINATION OF POLYCHLORINATED-BIPHENYLS IN ENVIRONMENTALLY CONTAMINATED SEDIMENTS [J].
ALFORDSTEVENS, AL ;
BUDDE, WL ;
BELLAR, TA .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2452-2457
[5]   SIMULTANEOUS DUAL-COLUMN, DUAL-DETECTOR GAS-CHROMATOGRAPHIC DETERMINATION OF CHLORINATED PESTICIDES AND POLYCHLORINATED-BIPHENYLS IN ENVIRONMENTAL-SAMPLES [J].
DURELL, GS ;
SAUER, TC .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1867-1871
[6]   ANALYTICAL METHODS FOR DETECTION OF NONOCCUPATIONAL EXPOSURE TO PESTICIDES [J].
HSU, JP ;
WHEELER, HG ;
CAMANN, DE ;
SCHATTENBERG, HJ ;
LEWIS, RG ;
BOND, AE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (04) :181-194
[7]   METHODS DEVELOPMENT AND IMPLEMENTATION FOR THE NATIONAL PESTICIDE SURVEY [J].
MUNCH, DJ ;
GRAVES, RL ;
MAXEY, RA ;
ENGEL, TM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (10) :1446-1451
[8]   EVALUATION OF A THERMAL-DESORPTION GAS-CHROMATOGRAPH MASS-SPECTROMETER - ON-SITE DETECTION OF POLYCHLORINATED-BIPHENYLS AT A HAZARDOUS-WASTE SITE [J].
ROBBAT, A ;
LIU, TY ;
ABRAHAM, BM .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :358-364
[9]  
ROBBAT A, 1982, ANAL CHEM, V64, P1477
[10]  
ROBBAT A, 1988, 1ST P INT S FIELD SC