A LEAD(II) ION-SELECTIVE ELECTRODE VIA A METAL-COMPLEX OF POLY(HYDROXAMIC ACID)

被引:14
|
作者
ANUAR, K
HAMDAN, S
机构
[1] Department of Chemistry, Faculty of Science and Environmental Studies, Universiti Pertanian Malaysia, 43400 UPM Serdang, Selangor
关键词
D O I
10.1016/0039-9140(92)80199-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new lead(II) electrode has been constructed with poly(hydroxamic acid) (PHXA) as the active material and silicone rubber as the supporting material. The electrode gave near Nernstian response over the concentration range 4 x 10(-5)-1 x 10(-2)M lead(II). The detection limit of the electrode is approximately 4 x 10(-6)M and the electrode works well in the pH range 4.5-6.0. The response time was 50-120 sec over the whole concentration range and the electrode has a working life of at least 4 weeks. Iron(III) severely poisoned the electrode membrane. Nickel(II) and mercury(II) gave very strong interference compared to copper(II), silver(I), cobalt(II), sodium(I), potassium(I), zinc(II) and cadmium(II) which gave some or little interference. Values determined with atomic absorption (AAS) and a commercial lead(II) electrode were in good agreement with those measured with the lead(II) electrode reported here.
引用
收藏
页码:1653 / 1656
页数:4
相关论文
共 50 条
  • [41] COMPLEX-FORMATION OF POLY(ACRYLIC ACID) WITH LEAD(II) ION
    HAYASHI, H
    KOMATSU, T
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1991, 64 (01) : 303 - 305
  • [42] BARIUM ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER COMPLEX
    LEVINS, RJ
    ANALYTICAL CHEMISTRY, 1972, 44 (08) : 1544 - &
  • [43] COPPER(I) ACTIVITY OF THE COPPER(II) ION-SELECTIVE ELECTRODE
    STUNZI, H
    TALANTA, 1982, 29 (01) : 75 - 76
  • [44] COATED WIRE ION-SELECTIVE ELECTRODE FOR DETERMINATION OF ZINC(II)
    CATTRALL, RW
    PUI, CP
    ANALYTICA CHIMICA ACTA, 1976, 87 (02) : 419 - 427
  • [45] Formation of metal complex in a poly(hydroxamic acid) resin bead
    Taek Seung Lee
    Dong Won Jeon
    Jai Kyeong Kim
    Sung Il Hong
    Fibers and Polymers, 2001, 2 (1) : 13 - 17
  • [46] TITRIMETRIC DETERMINATION OF TRACE SULFATE USING A LEAD ION-SELECTIVE ELECTRODE
    HEISTAND, RN
    BLAKE, CT
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1971, (MAR-A): : 38 - &
  • [47] INDIRECT DETERMINATION OF SULFATE BY DIRECT MEASUREMENT WITH A LEAD ION-SELECTIVE ELECTRODE
    VANSTADEN, JF
    WATER SA, 1986, 12 (04) : 225 - 228
  • [48] Lead ion-selective membrane electrode based on a novel fluorene derivative
    Yan, ZN
    Hou, YH
    Zhou, ZX
    Du, CX
    Wu, YJ
    ANALYTICAL LETTERS, 2004, 37 (15) : 3149 - 3159
  • [49] USE OF THE CU(II) ION-SELECTIVE ELECTRODE IN ESTUARINE MONITORING
    ZIRINO, A
    MARVIN, C
    DOTSON, P
    SELIGMAN, PF
    BOWER, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 119 - GEOC
  • [50] PREPARATION AND ANALYTICAL APPLICATIONS OF A COPPER(II) ION-SELECTIVE ELECTRODE
    DELRIO, MIG
    ARRIBAS, MCB
    BATANERO, PS
    ANALUSIS, 1983, 11 (03) : 131 - 135