A PORTABLE INSOLE PLANTAR PRESSURE MEASUREMENT SYSTEM

被引:44
作者
WERTSCH, JJ
WEBSTER, JG
TOMPKINS, WJ
机构
[1] CLEMENT J ZABLOCKI MED CTR,REHAB MED SERV,MILWAUKEE,WI 53295
[2] UNIV WISCONSIN,DEPT ELECT & COMP ENGN,MADISON,WI 53706
[3] MED COLL WISCONSIN,MILWAUKEE,WI 53226
来源
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT | 1992年 / 29卷 / 01期
关键词
ACTIVITIES OF DAILY LIVING (ADL); FOOT; GAIT; INSOLE SENSORS; PLANTAR PRESSURE; PORTABLE DATA ACQUISITION SYSTEM;
D O I
10.1682/JRRD.1992.01.0013
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
To analyze plantar pressures during activities of daily living, one needs a fully portable system capable of measuring many steps over extended periods. This paper presents an inexpensive, reliable, portable plantar pressure acquisition system which we have developed. It allows the long-term recording (up to 2 hours) of pressure-time data from 14 pressure sensors within insoles. The sensor chosen is an inexpensive, conductive polymer sensor that is only 0.25 mm thick yet able to withstand sudden overloads. The portable, battery-powered, microprocessor-based data acquisition system has a memory space of 480 kbytes for data storage. It can collect pressure data from 14 insole sensors at a 20 Hz sample frequency for 5 seconds every minute over a 2-hour period. It enables the long-term measurement of plantar pressures during normal activities in a natural unrestricted environment. The design and development of this portable insole plantar pressure measurement system is described.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 29 条
  • [1] [Anonymous], 1988, TACTILE SENSORS ROBO
  • [2] BAUMAN JH, 1963, LANCET, V1, P629
  • [3] BHAT S, 1989, NOV P ANN INT C IEEE, P1135
  • [4] BRODSKY JW, 1989, 1989 P AM ORTH FOOT, P24
  • [5] CHIZECK HJ, 1985, RESNA 8 ANN C, P379
  • [6] A load cell and sole assembly for dynamic pointwise vertical force measurement in walking
    Frost, R.B.
    Cass, C.A.
    [J]. Engineering in Medicine, 1981, 10 (01): : 45 - 50
  • [7] MEASUREMENT OF DISCRETE VERTICAL IN-SHOE STRESS WITH PIEZOELECTRIC TRANSDUCERS
    GROSS, TS
    BUNCH, RP
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (03): : 261 - 265
  • [8] HARRIS GF, 1988, 34TH P INT INSTR S I, P391
  • [9] Hennacy R A, 1975, J Am Podiatry Assoc, V65, P444
  • [10] A PIEZOELECTRIC METHOD OF MEASURING THE VERTICAL CONTACT STRESS BENEATH THE HUMAN FOOT
    HENNIG, EM
    CAVANAGH, PR
    ALBERT, HT
    MACMILLAN, NH
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1982, 4 (03): : 213 - 222