EFFECT OF MAGNETIC-RESONANCE-IMAGING ON IMPLANTABLE EYELID WEIGHTS

被引:16
|
作者
MARRA, S
KONIOR, TJ
LEONETTI, JP
RASLAN, W
机构
[1] LOYOLA UNIV,MED CTR,DEPT OTOLARYNGOL HEAD & NECK SURG,MAYWOOD,IL 60153
[2] LOYOLA UNIV,MED CTR,DEPT SURG PATHOL,MAYWOOD,IL 60153
来源
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY | 1995年 / 104卷 / 06期
关键词
GOLD WEIGHT IMPLANT; MAGNETIC RESONANCE IMAGING; UPPER EYELID IMPLANT;
D O I
10.1177/000348949510400606
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Implanted upper eyelid gold weights are used to prevent corneal injury in patients with facial nerve paralysis. Some of these individuals require postoperative radiographic surveillance for recurrent lateral skull base disease. Magnetic resonance imaging (MRI) provides the most accurate radiologic assessment; however, there is concern about the safety of performing MRI in patients with any metallic implant. Potential risks include local tissue heating and implant migration. Gold weights of 0.8 and 1.4 g were placed in an open chamber and were exposed to a magnetic field of 1.5 T. There was no measurable motion or displacement of the weights. The results were similar in 6 rats in which gold weights were subcutaneously implanted. Additionally, histologic examination of the implant sites revealed no adverse tissue effects attributable to MRI-generated heating of the implants. When carbon steel implants in the rat model were subjected to the magnetic field, there was no displacement of the implants and no adverse tissue effects were noted, despite the fact that a carbon steel implant in an open chamber demonstrated significant migration. The absence of motion of the gold weight implants combined with the lack of adverse tissue effects suggests the relative safety of performing MRI in patients with previously placed gold weights as upper eyelid implants.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [1] MAGNETIC-RESONANCE-IMAGING OF EYELID SPRINGS AND GOLD WEIGHTS
    GARDNER, TA
    RAK, KM
    ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (11) : 1498 - 1498
  • [2] MAGNETIC-RESONANCE-IMAGING OF THE UPPER EYELID ANATOMY
    MEYER, DR
    ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (10) : 1278 - 1278
  • [3] MAGNETIC-RESONANCE-IMAGING OF THE EYELID COMPLEX - ANATOMY AND PATHOLOGY
    MATURI, RK
    SOPARKAR, CNS
    PATRINELY, JR
    HAYMAN, LA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S501 - S501
  • [4] POTENTIAL HAZARD - TRACTION WEIGHTS AND MAGNETIC-RESONANCE-IMAGING
    JONES, AAM
    ARENA, MJ
    ZOLLER, JH
    STAR, AM
    COTLER, JM
    SPINE, 1991, 16 (03) : 364 - 365
  • [5] THE EFFECTS OF MAGNETIC-RESONANCE-IMAGING ON IMPLANTABLE PULSE GENERATORS
    HOLMES, DR
    HAYES, DL
    GRAY, JE
    MERIDETH, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (03): : 360 - 370
  • [6] EFFECTS OF MAGNETIC-RESONANCE-IMAGING FIELDS ON GOLD EYELID LOADS
    CANADY, JW
    MEINE, J
    THOMPSON, SA
    YUH, WTC
    ANNALS OF PLASTIC SURGERY, 1993, 31 (01) : 76 - 77
  • [7] EFFECTS OF MAGNETIC-RESONANCE-IMAGING ON IMPLANTABLE PERMANENT-MAGNETS
    SCHNEIDER, ML
    WALER, GB
    DORMER, KJ
    AMERICAN JOURNAL OF OTOLOGY, 1995, 16 (05): : 687 - 689
  • [8] MAGNETIC-RESONANCE-IMAGING
    TRESS, BM
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1986, 56 (03): : 188 - 189
  • [9] MAGNETIC-RESONANCE-IMAGING
    GINGELL, JC
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1990, 83 (07) : 471 - 473
  • [10] EFFECT OF THE SAMPLING RATE ON MAGNETIC-RESONANCE-IMAGING
    VINITSKI, S
    GRIFFEY, R
    FUKA, M
    MATWIYOFF, N
    PROST, R
    MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) : 278 - 285