Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging

被引:4
|
作者
O'Riordan, Cliona [1 ]
Van De Ven, Pepijn [2 ]
Nelson, John [2 ]
McCreesh, Karen [1 ]
Clifford, Amanda [1 ]
机构
[1] Univ Limerick, Dept Clin Therapies, Hlth Sci Bldg,2nd Floor, Limerick, Ireland
[2] Univ Limerick, Dept Sci & Engn, Limerick, Ireland
关键词
Real-time; ultrasound; longus colli; reliability;
D O I
10.1177/1742271X16659099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Real-time ultrasound imaging is an established objective outcome measurement with proven reliability. However, it is still largely biased by user-ability. Published research in the area of real-time ultrasound imaging reliability in the cervical region and in particular the deep cervical flexors is quite sparse. The purpose of this investigation was to examine if a novice ultrasound user could agree favourably with an experienced ultrasound sonographer in measuring the cross-sectional area of the longus colli. Methods Ultrasound images were captured from 22 healthy subjects on two different occasions, one week apart, by a novice ultrasound user. They were acquired using a GE Healthcare LOGIQe ultrasound machine, at a depth of 3-4cm with the transducer frequency set to 8MHz, in line with previous research guidelines. Cross-sectional area was then measured on-screen by both a novice and experienced ultrasound user to determine inter-rater reliability. Intra-rater reliability was also analysed using cross-sectional area figures from days one and two. Results Intra-rater reliability for real-time ultrasound imaging for the cross-sectional area of the longus colli was excellent (intra-class correlation 0.90, 95% CI 0.82-0.95). Inter-rater reliability was moderate but in keeping with previous published research (intra-class correlation 0.61, 95% CI 0.37-0.77). Conclusion Difficulties in identifying the borders of the longus colli muscle due to its deep anatomical location and surrounding structures make it difficult for assessors to agree favourably on cross-sectional area measurements, leading to moderate levels of inter-rater reliability and poor agreement. Intra-rater reliability is excellent, and in this instance indicates that a novice user can be just as reliable as a more experienced ultrasound user.
引用
收藏
页码:154 / 162
页数:9
相关论文
共 50 条
  • [31] Reliability of ultrasonography to measure cervical multifidus, semispinalis cervicis and longus colli muscles dimensions in patients with unilateral cervical disc herniation: An observational cross-sectional test-retest study
    Mohseni, Fariba
    Rahmani, Nahid
    Bandpei, Mohammad Ali Mohseni
    Abdollahi, Iraj
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2024, 37 : 399 - 403
  • [32] Real-time electronic patient evaluation of lymphedema symptoms, referral, and satisfaction: a cross-sectional study
    Nahum, Jennifer L.
    Fu, Mei R.
    Scagliola, Joan
    Rodorigo, Martha
    Tobik, Sandy
    Guth, Amber
    Axelrod, Deborah
    MHEALTH, 2021, 7 (02)
  • [33] Measurement of the cross-sectional area of the median and ulnar nerves by hand surgeons without ultrasound training: a prospective study
    Portney, Daniel A.
    Ross, Brendon S.
    Stepan, Jeffrey G.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2025,
  • [34] Correlation between semitendinosus and gracilis tendon cross-sectional area determined using ultrasound, magnetic resonance imaging and intraoperative tendon measurements
    Galanis, Nikiforos
    Savvidis, Matthaios
    Tsifountoudis, Ioannis
    Gkouvas, George
    Alafropatis, Ilias
    Kirkos, John
    Kellis, Eleftherios
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2016, 26 : 44 - 51
  • [35] Real-time ultrasound measures of lumbar erector spinae and multifidus: reliability and comparison to magnetic resonance imaging
    Belavy, D. L.
    Armbrecht, G.
    Felsenberg, D.
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (11) : 2285 - 2299
  • [36] Validity of ultrasound imaging for intrinsic foot muscle cross-sectional area measurements demonstrated by strong agreement with MRI
    Swanson, Dallin C.
    Sponbeck, Joshua K.
    Swanson, Derek A.
    Stevens, Conner D.
    Allen, Steven P.
    Mitchell, Ulrike H.
    George, James D.
    Johnson, Aaron Wayne
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [37] Validity of Ultrasound Imaging in Measuring Quadriceps Muscle Thickness and Cross-Sectional Area in Patients Receiving Maintenance Hemodialysis
    Sahathevan, Sharmela
    Khor, Ban-Hock
    Yeong, Chai Hong
    Tan, Teik Hin
    Mohaideen, Abdul Kareem Meera
    Ng, Hi Ming
    Ong, Gild Rick
    Narayanan, Sreelakshmi Sankara
    Gafor, Abdul Halim Abdul
    Goh, Bak Leong
    Bee, Boon Cheak
    Daud, Zulfitri 'Azuan Mat
    Chinna, Karuthan
    Karupaiah, Tilakavati
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2021, 45 (02) : 422 - 426
  • [38] STRENUOUS EXERCISE DECREASES MOTILITY AND CROSS-SECTIONAL AREA OF HUMAN GASTRIC ANTRUM - A STUDY USING ULTRASOUND
    BROWN, BP
    KETELAAR, MA
    SCHULZEDELRIEU, K
    ABUYOUSEF, MM
    BROWN, CK
    DIGESTIVE DISEASES AND SCIENCES, 1994, 39 (05) : 940 - 945
  • [39] PECTORALIS CROSS-SECTIONAL AREA CAN BE ACCURATELY MEASURED USING PANORAMIC ULTRASOUND: A VALIDITY AND REPEATABILITY STUDY
    Hernandez-Belmonte, Alejandro
    Martinez-Cava, Alejandro
    Pallares, Jesus G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (03) : 460 - 468
  • [40] Real-Time Ultrasound Detection of Breast Microcalcifications Using Multifocus Twinkling Artifact Imaging
    Kang, Jinbum
    Han, Kanghee
    Song, Ilseob
    Kim, Kang-Sik
    Jang, Won Seuk
    Kim, Min Jung
    Yoo, Yangmo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (05) : 1300 - 1308