Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging

被引:4
|
作者
O'Riordan, Cliona [1 ]
Van De Ven, Pepijn [2 ]
Nelson, John [2 ]
McCreesh, Karen [1 ]
Clifford, Amanda [1 ]
机构
[1] Univ Limerick, Dept Clin Therapies, Hlth Sci Bldg,2nd Floor, Limerick, Ireland
[2] Univ Limerick, Dept Sci & Engn, Limerick, Ireland
关键词
Real-time; ultrasound; longus colli; reliability;
D O I
10.1177/1742271X16659099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Real-time ultrasound imaging is an established objective outcome measurement with proven reliability. However, it is still largely biased by user-ability. Published research in the area of real-time ultrasound imaging reliability in the cervical region and in particular the deep cervical flexors is quite sparse. The purpose of this investigation was to examine if a novice ultrasound user could agree favourably with an experienced ultrasound sonographer in measuring the cross-sectional area of the longus colli. Methods Ultrasound images were captured from 22 healthy subjects on two different occasions, one week apart, by a novice ultrasound user. They were acquired using a GE Healthcare LOGIQe ultrasound machine, at a depth of 3-4cm with the transducer frequency set to 8MHz, in line with previous research guidelines. Cross-sectional area was then measured on-screen by both a novice and experienced ultrasound user to determine inter-rater reliability. Intra-rater reliability was also analysed using cross-sectional area figures from days one and two. Results Intra-rater reliability for real-time ultrasound imaging for the cross-sectional area of the longus colli was excellent (intra-class correlation 0.90, 95% CI 0.82-0.95). Inter-rater reliability was moderate but in keeping with previous published research (intra-class correlation 0.61, 95% CI 0.37-0.77). Conclusion Difficulties in identifying the borders of the longus colli muscle due to its deep anatomical location and surrounding structures make it difficult for assessors to agree favourably on cross-sectional area measurements, leading to moderate levels of inter-rater reliability and poor agreement. Intra-rater reliability is excellent, and in this instance indicates that a novice user can be just as reliable as a more experienced ultrasound user.
引用
收藏
页码:154 / 162
页数:9
相关论文
共 50 条
  • [1] Cross-sectional area of the longus colli and cervical degenerative spondylolisthesis: A retrospective review evaluating this anatomic consideration
    Tran, Khoa S.
    Mazmudar, Aditya
    Paziuk, Taylor
    Lambrechts, Mark J.
    Tecce, Eric
    Blaber, Olivia
    Habbal, Daniel
    Okroj, Kamil
    Karamian, Brian A.
    Canseco, Jose A.
    Rihn, Jeffrey
    Hilibrand, Alan
    Kepler, Christopher K.
    Vaccaro, Alexander R.
    Schroeder, Gregory D.
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2022, 13 (04) : 421 - 426
  • [2] Cervical Multifidus and Longus Colli Ultrasound Differences among Patients with Cervical Disc Bulging, Protrusion and Extrusion and Asymptomatic Controls: A Cross-Sectional Study
    Javanshir, Khodabakhsh
    Ghafouri-Rouzbehani, Payam
    Zohrehvand, Amirhossein
    Naeimi, Arvin
    Fernandez-de-las-Penas, Cesar
    Nikbakht, Hossein-Ali
    Mousavi-Khatir, Seyedeh Roghayeh
    Valera-Calero, Juan Antonio
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [3] Comparison of the Cross-Sectional Area of Longus Colli Muscle Between Patients With Cervical Radicular Pain and Healthy Controls
    Noormohammadpour, Pardis
    Dehghani-Firouzabadi, Azime
    Mansournia, Mohammad Ali
    Mohseni-Bandpei, Mohammad Ali
    Moghaddam, Navid
    Miri, Mojtaba
    Kordi, Ramin
    PM&R, 2017, 9 (02) : 120 - 126
  • [4] Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound
    Pauloski, Barbara R.
    Yahnke, Kacey M.
    DYSPHAGIA, 2025, 40 (01) : 141 - 151
  • [5] RELIABILITY OF DISTAL HAMSTRING TENDON LENGTH AND CROSS-SECTIONAL AREA USING 3-D FREEHAND ULTRASOUND
    Ahinis, Chrysostomoss
    Kellis, Leftherios
    Afkou, Konstantinos
    Ellinoudis, Athanasios
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09) : 2579 - 2588
  • [6] Rehabilitative ultrasound imaging of the supraspinatus muscle: Intra- and interrater reliability of thickness and cross-sectional area
    Schneebeli, Alessandro
    Egloff, Michele
    Giampietro, Amelia
    Clijsen, Ron
    Barbero, Marco
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2014, 18 (02) : 266 - 272
  • [7] Evaluation of the Anatomical Cross-Sectional Area of Psoas Major Muscle Using an Ultrasound Imaging System Combined With an Inertial Measurement Unit
    Ito, Kazuhiro
    Maeshima, Etsuko
    Arai, Nobuyuki
    Saito, Koichi
    Koshiba, Hiroya
    Maruyama, Junko
    Asada, Keiji
    Nakamata, Takaaki
    Yamaguchi, Kazuki
    Hatanaka, Yasuhiko
    TRANSLATIONAL SPORTS MEDICINE, 2024, 2024
  • [8] Intra-rater reliability of transversus abdominis measurement by a novice examiner: Comparison of "freehand" to "probe force device" method of real-time ultrasound imaging
    Kennedy, Vanessa L.
    Flavell, Carol A.
    Doma, Kenji
    ULTRASOUND, 2019, 27 (03) : 156 - 166
  • [9] Serial measurement of cross-sectional area in peripheral vein grafts using three-dimensional ultrasound
    Leotta, DF
    Primozich, JF
    Beach, KW
    Bergelin, RO
    Strandness, DE
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) : 61 - 68
  • [10] Conductance method for time measurement of cross-sectional areas of the aorta
    Kornet, L
    Jansen, JRC
    Gussenhoven, EJ
    Hardeman, MR
    Hoeks, APG
    Versprille, A
    ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (02) : 141 - 150