DETERMINATION OF PARAQUAT AND DIQUAT IN LOW-MOISTURE FOOD CROPS USING SILICA COLUMN CLEANUP AND LIQUID-CHROMATOGRAPHY WITH UV DETECTION

被引:0
|
作者
CHICHILA, TMP
GILVYDIS, DM
机构
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sample cleanup method was developed for the determination of paraquat (PQ) and diquat (DQ) in low-moisture food crops. Low-moisture commodities, such as milled dry navy beans, are digested in acid. PQ and DO are isolated from the digestates by using a 4 g column of preconditioned silica gel. The analytes are concentrated and then determined by liquid chromatography with a silica analytical column, sodium chloride as an ion-pairing reagent, and acetonitrile as an organic modifier. PD and DO are determined simultaneously with a diode array UV absorbance detector. Recoveries for PQ and DO were determined on 3 different fortified low-moisture crops. Fortification levels ranged from 0.01 to 0.30 ppm; average recoveries ranged from 47.5% (DQ) to 95.3% (PQ).
引用
收藏
页码:1323 / 1328
页数:6
相关论文
共 50 条
  • [1] LIQUID-CHROMATOGRAPHIC DETERMINATION OF PARAQUAT AND DIQUAT IN CROPS USING A SILICA COLUMN WITH AQUEOUS IONIC MOBILE PHASE
    CHICHILA, TM
    WALTERS, SM
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1991, 74 (06): : 961 - 967
  • [2] DETERMINATION OF PARAQUAT AND DIQUAT BY LIQUID-CHROMATOGRAPHY THERMOSPRAY MASS-SPECTROMETRY
    YOSHIDA, M
    WATABIKI, T
    TOKIYASU, T
    ISHIDA, N
    JOURNAL OF CHROMATOGRAPHY, 1993, 628 (02): : 235 - 239
  • [3] SIMULTANEOUS DETERMINATION OF PARAQUAT AND DIQUAT IN HUMAN TISSUES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ITO, S
    NAGATA, T
    KUDO, K
    KIMURA, K
    IMAMURA, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (01): : 119 - 123
  • [4] DETERMINATION OF DIQUAT AND PARAQUAT IN WATER USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CONFIRMATION BY LIQUID-CHROMATOGRAPHY PARTICLE-BEAM MASS-SPECTROMETRY
    KAMBHAMPATI, I
    ROINESTAD, KS
    HARTMAN, TG
    ROSEN, JD
    FUKUDA, EK
    LIPPINCOTT, RL
    ROSEN, RT
    JOURNAL OF CHROMATOGRAPHY A, 1994, 688 (1-2) : 67 - 73
  • [5] SIMPLIFIED CLEANUP FOR THE DETERMINATION OF BENZIMIDAZOLIC FUNGICIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH UV DETECTION
    DIMUCCIO, A
    CAMONI, I
    VENTRIGLIA, M
    BARBINI, DA
    MAURO, M
    PELOSI, P
    GENERALI, T
    AUSILI, A
    GIROLIMETTI, S
    JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) : 145 - 152
  • [6] RAPID-DETERMINATION OF DEOXYNIVALENOL (VOMITOXIN) BY LIQUID-CHROMATOGRAPHY USING MODIFIED ROMER COLUMN CLEANUP
    CHANG, HL
    DEVRIES, JW
    LARSON, PA
    PATEL, HH
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1984, 67 (01): : 52 - 54
  • [7] DETERMINATION OF ZOPICLONE IN PLASMA USING COLUMN LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    ROYERMORROT, MJ
    RAMBOURG, M
    JACOB, I
    BAUER, P
    ROYER, RJ
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 581 (02): : 297 - 299
  • [8] ANALYTICAL METHOD FOR THE SIMULTANEOUS DETERMINATION OF DIQUAT AND PARAQUAT RESIDUES IN POTATOES BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY
    WOROBEY, BL
    PESTICIDE SCIENCE, 1987, 18 (04): : 245 - 257
  • [9] DETERMINATION OF AZTREONAM BY LIQUID-CHROMATOGRAPHY WITH UV AND AMPEROMETRIC DETECTION
    HUANG, XJ
    KOK, WT
    FABRE, H
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (14): : 2721 - 2733
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETERMINATION OF DOXORUBICIN AND DAUNORUBICIN IN PLASMA USING UV DETECTION AND COLUMN SWITCHING
    MIKAN, A
    LANAO, JM
    LOPEZ, FG
    HURLE, ADG
    BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (04) : 154 - 156