BLINDED-READER COMPARISON OF MAGNETIC-RESONANCE ANGIOGRAPHY AND DUPLEX ULTRASONOGRAPHY FOR CAROTID-ARTERY BIFURCATION STENOSIS

被引:123
作者
MITTL, RL
BRODERICK, M
CARPENTER, JP
GOLDBERG, HI
LISTRUD, J
MISHKIN, MM
BERKOWITZ, HD
ATLAS, SW
机构
[1] HOSP UNIV PENN,DEPT RADIOL,NEURORADIOL SECT,3400 SPRUCE ST,PHILADELPHIA,PA 19104
[2] HOSP UNIV PENN,DEPT VASC SURG,PHILADELPHIA,PA 19104
关键词
CAROTID ARTERY DISEASES; DIAGNOSTIC IMAGING; ULTRASONICS;
D O I
10.1161/01.STR.25.1.4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose We compared two-dimensional time-of-flight magnetic resonance angiography (MRA) and duplex ultrasonography with arteriography for the detection of 70% to 99% stenoses at the carotid artery bifurcation (ie, surgical disease according to findings of the North American Carotid Endarterectomy Trial). Methods Three blinded readers independently measured stenoses on MRA in 73 vessels from 38 patients. Duplex ultrasonography was available in 66 vessels from 35 of these patients, and blinded reading was performed by one reader. Comparison was made to arteriography. Results Magnetic resonance angiography demonstrated a sensitivity of 92.4%, specificity of 74.5%, and negative predictive value of 95.8% for 70% to 99% stenoses. Interobserver agreement was high (kappa=0.91). Absence of signal at stenoses with evidence of distal flow usually, but not always, corresponded to surgical disease. Duplex ultrasonography demonstrated a sensitivity of 81.0%, specificity of 82.2%, and negative predictive value of 90.2% for surgical disease. There was no significant difference between MRA and duplex ultrasonography for the sensitivity or specificity in detecting 70% to 99% stenoses (P>.1, exact form of the McNemar test). MRA had no false positives or false negatives for complete occlusions of the carotid artery, whereas duplex ultrasonography missed one occlusion and falsely called two patent vessels occluded. In seven cases, both MRA and duplex ultrasonography overestimated stenoses to miscategorize them as surgical disease. Conclusions Although the sensitivity and specificity of MRA and duplex ultrasonography are not significantly different for distinguishing surgical and nonsurgical degrees of stenosis at the carotid bifurcation, MRA has some advantages that may make it the screening test of choice. Concordant MRA and duplex ultrasonography for surgical disease does not necessarily obviate the need for catheter arteriography.
引用
收藏
页码:4 / 10
页数:7
相关论文
共 37 条
[1]  
ANDERSON CM, 1992, AM J NEURORADIOL, V13, P989
[2]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[3]  
BENDICK PJ, 1983, MED INSTRUM, V3, P220
[4]  
BORNSTEIN NM, 1988, ANN SURG, P315
[5]  
CLARK WM, 1981, AM J NEURORADIOL, V2, P443
[6]   MATCHMAKING AND MCNEMAR IN THE COMPARISON OF DIAGNOSTIC MODALITIES [J].
DWYER, AJ .
RADIOLOGY, 1991, 178 (02) :328-330
[7]   STENOSIS OF THE INTERNAL CAROTID-ARTERY - ASSESSMENT USING COLOR DOPPLER IMAGING COMPARED WITH ANGIOGRAPHY [J].
ERICKSON, SJ ;
MEWISSEN, MW ;
FOLEY, WD ;
LAWSON, TL ;
MIDDLETON, WD ;
QUIROZ, FA ;
MACRANDER, SJ ;
LIPCHIK, EO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) :1299-1305
[8]   EFFECTS OF TURBULENCE ON SIGNAL INTENSITY IN GRADIENT ECHO IMAGES [J].
EVANS, AJ ;
BLINDER, RA ;
HERFKENS, RJ ;
SPRITZER, CE ;
KUETHE, DO ;
FRAM, EK ;
HEDLUND, LW .
INVESTIGATIVE RADIOLOGY, 1988, 23 (07) :512-518
[9]   HOW TO MEASURE CAROTID STENOSIS [J].
FOX, AJ .
RADIOLOGY, 1993, 186 (02) :316-318
[10]   DUPLEX ULTRASOUND SCANNING OF THE CAROTID ARTERIES WITH VELOCITY SPECTRUM ANALYSIS [J].
GARTH, KE ;
CARROLL, BA ;
SOMMER, FG ;
OPPENHEIMER, DA .
RADIOLOGY, 1983, 147 (03) :823-827