A NATIONAL INTERCOMPARISON BETWEEN AUTOMATIC NETWORK ANALYZERS

被引:6
|
作者
BERGEAULT, E [1 ]
ACHKAR, J [1 ]
VALON, M [1 ]
HUYART, B [1 ]
机构
[1] TELECOM PARIS,F-75635 PARIS 13,FRANCE
关键词
D O I
10.1109/19.278613
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to estimate the accuracy of heterodyne Automatic Network Analyzers, LCIE organized an intercomparison in France. The intercomparison measurements were performed on six different passive microwave components at 2, 10, and 18 GHz. The measured results are compared to those given by the Calibration Center of LCIE and those obtained with the dual six-port reflectometer realized at BNM/LCIE. In this work, the measured results, in terms of complex reflection and transmission coefficients (amplitude, phase), obtained at different frequencies are reported.
引用
收藏
页码:511 / 515
页数:5
相关论文