GLASS-CAPILLARY COLUMNS COATED WITH NON-SOLUBLE METHYL SILICONE GUMS

被引:30
作者
BLOMBERG, L
WANNMAN, T
机构
[1] Department of Analytical Chemistry, University of Stockholm, Arrhenius Laboratory
来源
JOURNAL OF CHROMATOGRAPHY | 1979年 / 186卷 / DEC期
关键词
D O I
10.1016/S0021-9673(00)95244-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When used as stationary phases in glass capillary columns, films formed from gums are generally more stable than liquid phases. The stability indicates that a high column efficiency can be maintained at elevated temperatures, column bleeding is low and the column lifetime is long. In this paper we present a method for increasing further the gum film stability by using gums with a higher degree of cross-linking. Such gums are not soluble in commonly used solvents and are therefore synthesized in situ. In addition, measures have been taken to promote chemical bonding between glass and polymer. The columns have been used successfully for the routine analysis of polyaromatic hydrocarbons. © 1979.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 16 条
[1]  
ANDRIANOV KA, 1965, METALORGANIC POLYMER
[2]   MEASUREMENT OF AVERAGE THICKNESS OF FILM OF STATIONARY PHASE IN DYNAMICALLY COATED GLASS CAPILLARY COLUMNS FOR GAS-CHROMATOGRAPHY [J].
BLOMBERG, L .
JOURNAL OF CHROMATOGRAPHY, 1977, 138 (01) :7-16
[3]   PREPARATION OF THERMOSTABLE, PHENYL SILICONE COATED, GLASS CAPILLARY COLUMNS FOR SEPARATION OF POLYAROMATIC HYDROCARBONS [J].
BLOMBERG, L ;
BUIJTEN, J ;
GAWDZIK, J ;
WANNMAN, T .
CHROMATOGRAPHIA, 1978, 11 (09) :521-525
[4]   SOME FACTORS AFFECTING PROPERTIES OF THIN-FILMS OF CARBOWAX20M INTENDED FOR DEACTIVATION OF GLASS CAPILLARY COLUMNS [J].
BLOMBERG, L ;
WANNMAN, T .
JOURNAL OF CHROMATOGRAPHY, 1978, 148 (02) :379-387
[5]   INSITU SYNTHESIS OF HIGHLY THERMOSTABLE, NON-EXTRACTABLE, METHYLSILICONE GUM PHASES FOR GLASS CAPILLARY GAS-CHROMATOGRAPHY [J].
BLOMBERG, L ;
WANNMAN, T .
JOURNAL OF CHROMATOGRAPHY, 1979, 168 (01) :81-88
[6]   ARE WE USING FULL RANGE OF FILM THICKNESS IN CAPILLARY-GLC [J].
GROB, K ;
GROB, K .
CHROMATOGRAPHIA, 1977, 10 (05) :250-255
[7]   GUM PHASES FOR GLASS CAPILLARY COLUMNS - RECOMMENDATION FOR USERS, A CHALLENGE FOR POLYMER SCIENTISTS [J].
GROB, K .
CHROMATOGRAPHIA, 1977, 10 (10) :625-625
[8]   BARIUM CARBONATE PROCEDURE FOR PREPARATION OF GLASS CAPILLARY COLUMNS - FURTHER INFORMATIONS AND DEVELOPMENTS [J].
GROB, K ;
GROB, G ;
GROB, K .
CHROMATOGRAPHIA, 1977, 10 (04) :181-187
[9]  
Grob K., 1979, J HIGH RES CHROMATOG, V2, P31
[10]   USE OF HYDROLYZED CHLOROSILANES FOR PREPARATION OF HIGH-RESOLUTION GLASS CAPILLARY COLUMNS [J].
MADANI, C ;
CHAMBAZ, EM ;
RIGAUD, M ;
CHEBROUX, P ;
BRETON, JC ;
BERTHOU, F .
CHROMATOGRAPHIA, 1977, 10 (08) :466-472