Post-Occupancy Evaluation of State Schools in 5 Climatic Zones of Chile

被引:0
作者
Armijo, Gabriela [1 ]
Whitman, Christopher J. [1 ]
Casals, Roberto [1 ]
机构
[1] Univ Cent Chile, Fac Architecture Urbanism & Landscape, Lab Bioclimat, Santiago, Chile
来源
GAZI UNIVERSITY JOURNAL OF SCIENCE | 2011年 / 24卷 / 02期
关键词
Schools; Comfort; Post-Occupancy Evaluation; Indoor air quality; monitoring;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents the results of a study, commissioned by the Chilean Ministry of Education and UNESCO, of hygro-thermal comfort, visual comfort, acoustics and indoor air quality, as experienced in selected classrooms of 8 state schools located in distinct climatic zones in Chile. Using a post-occupancy evaluation methodology developed by the authors, 14 classrooms were evaluated with visual analysis, questionnaires and insitu measurements over a 5 day period. Although limited in its duration, the study clearly highlighted deficits in each of the areas of study; these included unacceptable sound pollution arising from transport; overheating due to excessive solar gain; insufficient heating and poorly insulated building fabric; poor indoor air quality; and poor day and electric lighting.
引用
收藏
页码:365 / 374
页数:10
相关论文
共 50 条
  • [21] Framework model for post-occupancy evaluation of school facilities
    Hassanain, Mohammad A.
    Iftikhar, Ali
    Structural Survey, 2015, 33 (4-5) : 322 - 336
  • [22] Seeing is believing: an innovative approach to post-occupancy evaluation
    Day, Julia K.
    Ruiz, Shelby
    O'Brien, William
    Schweiker, Marcel
    ENERGY EFFICIENCY, 2020, 13 (03) : 473 - 486
  • [23] An exploration of post-occupancy evaluation in Canada: origins, milestones and next steps
    Boissonneault, Alexandra
    Peters, Terri
    BUILDING RESEARCH AND INFORMATION, 2024, 52 (03) : 332 - 357
  • [24] Ten years on: a post-occupancy evaluation of classrooms for pupils with severe autism
    Irish, Julie E. N.
    FACILITIES, 2022, 40 (9/10) : 656 - 674
  • [25] Post-Occupancy Evaluation of Housing Facilities: Overview and Summary of Methods
    Sanni-Anibire, Muizz O.
    Hassanain, Mohammad A.
    Al-Hammad, Abdul-Mohsen
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2016, 30 (05)
  • [26] How do post-occupancy evaluation and the facilities manager meet?
    Eley, J
    BUILDING RESEARCH AND INFORMATION, 2001, 29 (02) : 164 - 167
  • [27] Indoor Environmental Quality Assessment and Occupant Satisfaction: A Post-Occupancy Evaluation of a UAE University Office Building
    Kim, Young Ki
    Abdou, Yasmin
    Abdou, Alaa
    Altan, Hasim
    BUILDINGS, 2022, 12 (07)
  • [28] Post-occupancy evaluation of healing gardens in a pediatric cancer center
    Sherman, SA
    Varni, JW
    Ulrich, RS
    Malcarne, VL
    LANDSCAPE AND URBAN PLANNING, 2005, 73 (2-3) : 167 - 183
  • [29] Post-occupancy evaluation for enhancing building performance and automation deployment
    Al Mughairi, Majid
    Beach, Thomas
    Rezgui, Yacine
    JOURNAL OF BUILDING ENGINEERING, 2023, 77
  • [30] Rooftop Hospital Gardens for Physical Therapy: A Post-Occupancy Evaluation
    Davis, Brad E.
    HERD-HEALTH ENVIRONMENTS RESEARCH & DESIGN JOURNAL, 2011, 4 (03) : 14 - 43