DETERMINATION OF RARE-EARTH ELEMENTS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ION CHROMATOGRAPHY

被引:85
作者
KAWABATA, K
KISHI, Y
KAWAGUCHI, O
WATANABE, Y
INOUE, Y
机构
[1] Analytical Instruments Division, Yokogawa Electric Corporation, Musashino-shi
关键词
D O I
10.1021/ac00019a013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma mass spectrometry (ICPMS) has been used for analysis of trace rare-earth elements as impurities that exist in other rare-earth material. ICPMS attains the pg.mL-1 level detection in solution for all of the rare-earth elements by means of conventional introduction system. On the other hand, an interference problem due to polyatomic ions is well-known and is especially critical for determination of the rare-earth elements. In order to solve this problem, the ion chromatographic analyzer was combined with ICPMS. After separation from a main material by ion chromatography (IC), trace rare-earth elements were directly introduced to ICPMS and analyzed. The detection limits for 14 rare-earth elements were from 1 to 5 pg.mL-1 in solution and ng.g-1 in solid. The linear range was 10(6), from 10 pg.mL-1 to 10-mu-g.mL-1, and the repeatability was better than +/- 1% of the relative standard deviation (RSD) for Lu.
引用
收藏
页码:2137 / 2140
页数:4
相关论文
共 14 条
[1]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[2]   DETERMINATION OF RARE-EARTH ELEMENTS IN GEOLOGICAL SAMPLES BY INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY [J].
DATE, AR ;
HUTCHISON, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (03) :269-276
[4]   SIMULTANEOUS DETERMINATION OF MAJOR AND TRACE-ELEMENTS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY OPTICAL-EMISSION SPECTROMETRY [J].
GARBARINO, JR ;
TAYLOR, HE ;
BATIE, WC .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :793-796
[5]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474
[6]   OXIDE AND DOUBLY CHARGED ION RESPONSE OF A COMMERCIAL INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY INSTRUMENT [J].
GRAY, AL ;
WILLIAMS, JG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (01) :81-82
[7]   INDUCTIVELY COUPLED ARGON PLASMA AS AN ION-SOURCE FOR MASS-SPECTROMETRIC DETERMINATION OF TRACE-ELEMENTS [J].
HOUK, RS ;
FASSEL, VA ;
FLESCH, GD ;
SVEC, HJ ;
GRAY, AL ;
TAYLOR, CE .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2283-2289
[8]   AVOIDANCE OF SPECTRAL INTERFERENCE ON EUROPIUM IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY SENSITIVE MEASUREMENT OF THE DOUBLY CHARGED ION [J].
JARVIS, KE ;
GRAY, AL ;
MCCURDY, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) :743-747
[9]  
Kano T., 1980, RARE EARTHS PROPERTI
[10]   REVIEW OF METHODS FOR THE DETERMINATION OF LANTHANIDES IN GEOLOGICAL SAMPLES [J].
KANTIPULY, CJ ;
WESTLAND, AD .
TALANTA, 1988, 35 (01) :1-13