Thermal Peak Load Shaving Through Users Request Variations in District Heating Systems

被引:28
作者
Verda, V. [1 ]
Guelpa, E. [1 ]
Sciacovelli, A. [2 ]
Acquaviva, A. [3 ]
Patti, E. [3 ]
机构
[1] Politecn Torino, Dipartimento Energia, Turin, Italy
[2] Birmingham Ctr Energy Storage, Sch Chem Engn, Birmingham, W Midlands, England
[3] Politecn Torino, Dipartimento Automat & Informat, Turin, Italy
关键词
District heating operation; thermal fluid dynamic model; building request; virtual thermal storage;
D O I
10.5541/ijot.5000175955
中图分类号
O414.1 [热力学];
学科分类号
摘要
Peak shaving is a relatively new approach aimed at increasing the primary energy efficiency in District Heating Systems. This is mainly performed using thermal storage units that can be charged when the thermal request is small, usually at night, and discharged to cover peak requests. Thermal storage typically allows one increasing the utilization of waste heat, renewables and cogeneration systems while reducing the use of boilers. An alternative option to conventional thermal storage is "virtual storage". This consists in modifying the thermal request profiles of buildings in order to reduce their contributions in peak hours. Such modifications rely on the thermal capacity of buildings in order to comply with end-user requirements on the internal temperatures. The analysis of possible operational strategies should be performed using an integrated simulation, which considers both the thermos-fluid dynamic behavior of the network and the thermal behavior of the buildings. In this paper, a physical tool specifically conceived for the analysis of peak shaving in large networks through virtual storage is presented and applied to a portion of the Turin district heating network. Detailed information about thermal requests of buildings obtained from a pervasive metering system is used in order to characterize their behavior. This piece of information is then adopted for constraining and checking possible different operational strategies. Two different scenarios are analyzed and compared with current operation in terms of primary energy consumption, showing that primary energy savings of the order of 5% can be achieved without affecting the comfort perceived by the users.
引用
收藏
页码:168 / 176
页数:9
相关论文
共 15 条
[1]   An Optimization Procedure for District Heating Networks [J].
Ancona, M. A. ;
Melino, F. ;
Peretto, A. .
INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 :278-281
[2]   Linear programming optimization of heat distribution in a district-heating system by valve adjustments and substation retrofit [J].
Bojic, M ;
Trifunovic, N .
BUILDING AND ENVIRONMENT, 2000, 35 (02) :151-159
[3]   Numerical analysis of a medium scale latent energy storage unit for district heating systems [J].
Colella, Francesco ;
Sciacovelli, Adriano ;
Verda, Vittorio .
ENERGY, 2012, 45 (01) :397-406
[4]  
FERZIGER JH, 2001, COMPUTATIONAL METHOD
[5]  
Guelpa E., 2015, P ASME IMECE HOUST T
[6]  
Harary F., 1995, GRAPH THEORY
[7]  
Jokinen E., 2014, ECOS 2014
[8]   Optimization of solar district heating systems:: seasonal storage, heat pumps, and cogeneration [J].
Lindenberger, D ;
Bruckner, T ;
Groscurth, HM ;
Kümmel, R .
ENERGY, 2000, 25 (07) :591-608
[9]   The role of district heating in future renewable energy systems [J].
Lund, H. ;
Moller, B. ;
Mathiesen, B. V. ;
Dyrelund, A. .
ENERGY, 2010, 35 (03) :1381-1390
[10]  
Patankar S., 1980, NUMERICAL HEAT TRANS