Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

被引:0
作者
Pourjavid, A. [1 ]
Ghahraman, Adel [1 ]
Sedaie, M. [1 ]
Farhadi, M. [2 ]
Daneshi, A. [2 ]
Zarandi, Motesadi [3 ]
Emamjome, H. [3 ]
Mobedshahi, F. [4 ]
Kabirrah, Abbasalipour [4 ]
Faghihzadeh, S.
机构
[1] Univ Tehran Med Sci, Audiol, Tehran, Iran
[2] Iran Univ Med Sci, Tehran, Iran
[3] Univ Tehran Med Sci, Tehran, Iran
[4] Tarbiat Modares Univ, Tehran, Iran
来源
ARCHIVES OF REHABILITATION | 2012年 / 13卷 / 01期
关键词
Electrically evoked compound action potential; Neural response telemetry; Cochlear implant;
D O I
暂无
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and monitoring the intra and postoperative responses of auditory nerve and help to primary setting of speech processor. The aim of this study was evaluating the potential's slope of amplitude growth function changes three monthes after receiving the devise in pediatric cochlear implant recipients. Materials & Methods: This longitudinal study evaluated the potentials' slope of amplitude growth function changes in four given electrodes in four sessions after receiving the devise by approximately one month's intervals in all of the children who implanted in Amir Alam and Hazrate-Rasoul hospitals in 2007, July to December. Friedman test was used to analyse the results. Results: Electrically evoked compound action potential's mean slope of each electrode was more in later sessions relative to first session, while there was significant difference between the 1st and the other electrodes' responses in every session(P<0.05). Conclusion: The reliabiliy of the responses results in more assurance of clinician to fit the speech processor for along time. Better responses in apical electrodes may lead to develope an effective coding strategy.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 16 条
[1]   Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential [J].
Abbas, PJ ;
Brown, CJ ;
Shallop, JK ;
Firszt, JB ;
Hughes, ML ;
Hong, SH ;
Staller, SJ .
EAR AND HEARING, 1999, 20 (01) :45-59
[2]  
Brown C, 2003, COCHLEAR IMPLANTS OB, P96
[3]   Electrically evoked whole nerve action potentials in ineraid cochlear implant users: Responses to different stimulating electrode configurations and comparison to psychophysical responses [J].
Brown, CJ ;
Abbas, PJ ;
Borland, J ;
Bertschy, MR .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1996, 39 (03) :453-467
[4]  
Brown CJ, 1998, AM J OTOL, V19, P320
[5]   Preliminary neural response telemetry results [J].
Cullington, H .
BRITISH JOURNAL OF AUDIOLOGY, 2000, 34 (03) :131-140
[6]   Normative findings of electrically evoked compound action potential measurements uing the neural response telemetry of the nucleus CI24M cochlear implant system [J].
Dees, DC ;
Dillier, N ;
Lai, WK ;
von Wallenberg, E ;
van Dijk, B ;
Akdas, F ;
Aksit, M ;
Batman, C ;
Beynon, A ;
Burdo, S ;
Chanal, JM ;
Collet, L ;
Conway, M ;
Coudert, C ;
Craddock, L ;
Cullington, H ;
Deggouj, N ;
Fraysse, B ;
Grabel, S ;
Kiefer, J ;
Kiss, JG ;
Lenarz, T ;
Mair, A ;
Maune, S ;
Müller-Deile, J ;
Piron, JP ;
Razza, S ;
Tasche, C ;
Thai-Van, H ;
Toth, F ;
Truy, E ;
Uziel, A ;
Smoorenburg, GF .
AUDIOLOGY AND NEURO-OTOLOGY, 2005, 10 (02) :105-116
[7]   Measurement of the electrically evoked compound action potential via a neural response telemetry system [J].
Dillier, N ;
Lai, WK ;
Almqvist, B ;
Frohne, C ;
Müller-Deile, J ;
Stecker, M ;
von Wallenberg, E .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (05) :407-414
[8]   Electrically evoked compound action potential amplitude growth functions and HiResolution programming levels in pediatric CII implant subjects [J].
Eisen, MD ;
Franck, KH .
EAR AND HEARING, 2004, 25 (06) :528-538
[9]  
Flynn S, 2003, COCHLEAR IMPLANTS YO, P11
[10]   A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in Nucleus 24 cochlear implant users [J].
Hughes, ML ;
Werff, KRV ;
Brown, CJ ;
Abbas, PJ ;
Kelsay, DMR ;
Teagle, HFB ;
Lowder, MW .
EAR AND HEARING, 2001, 22 (06) :471-486