IOVERSOL 350 - CLINICAL-EXPERIENCE IN CRANIAL COMPUTED-TOMOGRAPHY

被引:0
|
作者
THERON, J
PAUGAM, JP
COURTHEOUX, P
机构
关键词
IOVERSOL; CONTRAST MEDIA; HEAD; CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A single, open trial was conducted in 40 patients to evaluate the diagnostic efficacy and safety, in cranial computed tomography, of ioversol (350 mgl/ml), a new nonionic, monomeric, low-osmolality contrast medium. Ioversol is characterized by a hydrophilicity which is not only the highest of all nonionic agents available to date, but also evenly distributed among the various sides of the benzene ring. Diagnosis was possible in 100% of cases with a mean degree of certainty of 90.8%. Six minor adverse reactions requiring no treatment were recorded, of which two were observed by the investigator and four reported by the patients. No pain sensation was found and heat sensations were of minor intensity. Ioversol 350, which showed good diagnostic efficacy and proved to be well tolerated, is therefore suitable for cranial computed tomography at a mean dose of 1 ml/kg.
引用
收藏
页码:413 / 417
页数:5
相关论文
共 50 条
  • [41] RADIATION EXPOSURE OF THE EYES IN CRANIAL COMPUTED-TOMOGRAPHY
    LUND, E
    HALABURT, H
    NEURORADIOLOGY, 1980, 20 (05) : 278 - 278
  • [42] CRANIAL COMPUTED-TOMOGRAPHY IN ACUTE DISSEMINATED ENCEPHALOMYELITIS
    THAJEB, P
    CHEN, ST
    NEURORADIOLOGY, 1989, 31 (01) : 8 - 12
  • [43] THE EXCESSIVELY SMALL VENTRICLE ON CRANIAL COMPUTED-TOMOGRAPHY - CLINICAL CORRELATION IN 75 PATIENTS
    AUH, YH
    LEE, SH
    TOGLIA, JU
    CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1980, 4 (04): : 325 - 329
  • [44] CLINICAL-EXPERIENCE WITH THE ROYAL MARSDEN HOSPITAL COMPUTED-TOMOGRAPHY SIMULATOR APPLIED TO PLANNING RADIOTHERAPY TREATMENT FOR BREAST-CANCER
    WEBB, S
    LEACH, MO
    BENTLEY, RE
    MAUREEMOOTOO, K
    TOMS, MA
    YARNOLD, J
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 831 - 831
  • [45] NUCLEAR MAGNETIC-RESONANCE IMAGING IN ABDOMINAL AND PELVIC DISEASE - INITIAL CLINICAL-EXPERIENCE IN COMPARISON WITH COMPUTED-TOMOGRAPHY AND ULTRASONOGRAPHY
    RODL, W
    LUTZ, H
    OPPELT, A
    HEPATO-GASTROENTEROLOGY, 1983, 30 (02) : 37 - 41
  • [46] 3-D CRANIAL AND SPINAL COMPUTED-TOMOGRAPHY
    BECKER, H
    RADIOLOGE, 1988, 28 (05): : 239 - 242
  • [47] CRANIAL COMPUTED-TOMOGRAPHY IN MAPLE SYRUP URINE DISEASE
    IRNBERGER, T
    PLOCHL, E
    RITTINGER, O
    BACHMANN, C
    PILZ, P
    WALTER, GF
    WENDEL, U
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1986, 144 (04): : 413 - 417
  • [48] CRANIAL COMPUTED-TOMOGRAPHY - MORE INVESTIGATIONS AND INCREASED COST
    SAGER, WD
    SCHREYER, H
    LEPUSCHUTZ, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1981, 106 (06) : 163 - 164
  • [49] COMPUTED-TOMOGRAPHY OF A CRANIAL WOODEN FOREIGN-BODY
    HEALY, JF
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) : 555 - 556
  • [50] COMPUTED-TOMOGRAPHY OF THE HEART - INITIAL EXPERIENCE
    BARTER, SJ
    STEINER, RE
    BANKS, L
    DEANFIELD, J
    MASERI, A
    CLINICAL RADIOLOGY, 1983, 34 (06) : 693 - 699