Comparison of ocular biometry measurements by applanation and immersion A-scan techniques

被引:14
作者
Ademola-Popoola, Dupe S. [1 ,2 ]
Nzeh, Donald A. [1 ]
Saka, Sadiat E. [2 ]
Olokoba, Lateefat B. [2 ]
Obajolowo, Tokunbo S. [2 ]
机构
[1] Univ Ilorin, Dept Radiol, Ilorin, Kwara State, Nigeria
[2] Univ Ilorin, Teaching Hosp, Dept Ophthalmol, Old Jebba Rd,GPO Box 4718, Ilorin, Kwara State, Nigeria
来源
JOURNAL OF CURRENT OPHTHALMOLOGY | 2015年 / 27卷 / 3-4期
关键词
Ocular biometry; Applanation; Immersion; Techniques; Adults; Training;
D O I
10.1016/j.joco.2015.12.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The study compared ocular biometry values using applanation and immersion techniques to determine the most applicable method for our tertiary training centre where personnel with different levels of experience and expertise in biometry take measurements used in calculation of required intraocular lens before cataract surgery. Methods: The study was a prospective cross-sectional comparative study of different techniques of ocular biometry from diagnostic equipment (biometry probe 10 MHz Sonomed (R) A-scan (PACSCAN 300A, USA). Measurement variables were obtained among children and adults undergoing cataract surgery. Scleral (Prager) shell was used for the immersion technique followed by the contact technique by the same examiner. Results: The biometry values of 92 eyes of 92 adult were taken. Their ages ranged from 18 to 95 years with a mean of 64.7 (SD +/- 12.9) years. There were 55 (59.8%) males and 37 (40.2%) females, with a male to female ratio of 1.5:1. Average axial length (22.0-24.4 mm) eyes were the most common eyes measured in 75 (81.5%) of the cases. The means of the axial lengths biometry values with immersion and contact technique were 23.66(+/- 1.36) and 23.46 mm (+/- 1.46); the axial length differences was 0.2 +/- 0.26 mm (range 0.0-0.94 mm) and statistically significant (95% CI of the Difference 0.15 to 0.26, p = 0.000). The Standard deviation SD (mm) of Individual Eye Axial Length showed a mean of 0.03 +/- 0.04 (0.0-0.3) mm for immersion and for contact technique 0.14 +/- 0.12(0.0-0.6) mm. Conclusion: There was a significant difference in ocular biometry measurement with the contact and immersion ultrasound techniques. The immersion technique had better repeatability, thus it is ideal in a training hospital setting in a typical in sub-Saharan Africa who have limited resources to employ a dedicated person to do biometry; and where the different operators of A-scan machines have different levels of experience and expertise. Copyright (C) 2015, Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V.
引用
收藏
页码:110 / 114
页数:5
相关论文
共 28 条
  • [1] IMMERSION B-GUIDED VERSUS CONTACT A-MODE BIOMETRY FOR ACCURATE MEASUREMENT OF AXIAL LENGTH AND INTRAOCULAR LENS POWER CALCULATION IN SILICONIZED EYES
    Abu El Einen, Khaled G.
    Shalaby, Mervat H.
    El Shiwy, Hoda T.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (02): : 262 - 265
  • [2] [Anonymous], 2011, BAS CLIN SCI COURS, P211
  • [3] Intraocular lens formula constant optimization and partial coherence interferometry biometry: Refractive outcomes in 8108 eyes after cataract surgery
    Aristodemou, Petros
    Cartwright, Nathaniel E. Knox
    Sparrow, John M.
    Johnston, Robert L.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) : 50 - 62
  • [4] Attah H, 2008, OPHTHALMIC ULTRASOUN, P555
  • [5] Accuracy of IOL calculations in children: A comparison of immersion versus contact A-scan biometery
    Ben-Zion, Itay
    Neely, Daniel E.
    Plager, David A.
    Ofner, Susan
    Sprunger, Derek T.
    Roberts, Gavin J.
    [J]. JOURNAL OF AAPOS, 2008, 12 (05): : 440 - 444
  • [6] Falhar M, 2010, OPT APPL, V40, P77
  • [7] Fontes BM, ARQ BRASOFTALMOL, V74, P166
  • [8] Benchmark standards for refractive outcomes after NHS cataract surgery
    Gale, R. P.
    Saldana, M.
    Johnston, R. L.
    Zuberbuhler, B.
    McKibbin, M.
    [J]. EYE, 2009, 23 (01) : 149 - 152
  • [9] National biometry audit II
    Gale, RP
    Saha, N
    Johnston, RL
    [J]. EYE, 2006, 20 (01) : 25 - 28
  • [10] Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    Haigis, W
    Lege, B
    Miller, N
    Schneider, B
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) : 765 - 773