USE OF DIPLOID AND TRIPLOID TROUT ERYTHROCYTES AS INTERNAL STANDARDS IN FLOW-CYTOMETRY

被引:12
作者
PIERREZ, J
RONOT, X
机构
[1] ECOLE PRAT HAUTES ETUD,PARIS,FRANCE
[2] UNIV JOSEPH FOURIER,GRENOBLE,FRANCE
来源
CYTOMETRY | 1991年 / 12卷 / 03期
关键词
STANDARDIZATION; LEUCOCENTRATION TECHNIQUE; MITHRAMYCIN;
D O I
10.1002/cyto.990120311
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
DNA content determination requires the use of standards. Vindelov has shown the need to use two standards. Chicken and trout erythrocytes are commonly used, but they are not ideal standards. On the one hand, their DNA contents rarely frame the studied sample DNA content, and, on the other hand, as their base compositions are different in terms of A + T/G + C, their relative indices change according to the stains used. Use of triploid trout erythrocytes instead of chicken erythrocytes allows elimination of these two drawbacks; however, diploid trout must be differentiated from triploid trout. The present paper shows that an anatomic malformation is found with the triploid trout and so justifies the use of paired diploid and triploid trout as standards to measure nuclear DNA content.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 11 条
  • [1] FLOW-CYTOGENETICS - SOURCES OF DNA CONTENT VARIATION AMONG EUPLOID INDIVIDUALS
    HOEHN, H
    JOHNSTON, P
    CALLIS, J
    [J]. CYTOGENETICS AND CELL GENETICS, 1977, 19 (2-3): : 94 - 107
  • [2] HOURROUD C, 1982, REPROD NUTR DEV, V20, P727
  • [3] TROUT AND SALMON ERYTHROCYTES AND HUMAN-LEUKOCYTES AS INTERNAL STANDARDS FOR PLOIDY CONTROL IN FLOW-CYTOMETRY
    IVERSEN, OE
    LAERUM, OD
    [J]. CYTOMETRY, 1987, 8 (02): : 190 - 196
  • [4] THE USE OF TROUT ERYTHROCYTES AND HUMAN-LYMPHOCYTES FOR STANDARDIZATION IN FLOW-CYTOMETRY
    JAKOBSEN, A
    [J]. CYTOMETRY, 1983, 4 (02): : 161 - 165
  • [5] TECHNIQUE AND STAINING OPTIMIZATION LEUKOCONCENTRATION
    PIERREZ, J
    GUERCI, A
    GUERCI, O
    [J]. CYTOMETRY, 1987, 8 (05): : 529 - 533
  • [6] FLOW CYTOMETRIC ANALYSIS OF DNA CONTENT DIFFERENCES IN BLOOD-SAMPLES OBTAINED BY LEUKOCONCENTRATION
    PIERREZ, J
    GUERCI, A
    GUERCI, O
    [J]. CYTOMETRY, 1988, 9 (04): : 299 - 302
  • [7] THOGAARD GH, 1983, FISH PHYSL 9, P405
  • [8] REFERENCE-STANDARDS FOR FLOW-CYTOMETRY AND APPLICATION IN COMPARATIVE STUDIES OF NUCLEAR-DNA CONTENT
    TIERSCH, TR
    CHANDLER, RW
    WACHTEL, SS
    ELIAS, S
    [J]. CYTOMETRY, 1989, 10 (06): : 706 - 710
  • [9] TOULMIN S, 1963, FORESIGHT UNDERSTAND
  • [10] STANDARDIZATION OF HIGH-RESOLUTION FLOW CYTOMETRIC DNA ANALYSIS BY THE SIMULTANEOUS USE OF CHICKEN AND TROUT RED-BLOOD-CELLS AS INTERNAL REFERENCE-STANDARDS
    VINDELOV, LL
    CHRISTENSEN, IJ
    NISSEN, NI
    [J]. CYTOMETRY, 1983, 3 (05): : 328 - 331