Purpose: Setup deviations of a craniospinal irradiation (CSI) patient cohort previously treated with helical tomotherapy were used to derive the optimal planning target volume (PTV) margin for CSI patients treated in the supine position. Methods and Materials: The daily setup shifts of 27 CSI tomotherapy patients as determined using pretreatment megavoltage computed tomography verification for a total of 454 fractions were evaluated. Translational displacements in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) directions were used to assess the systematic and random setup errors, and to derive the PTV margin required when daily image guidance is unavailable. Results: The individual patient mean shifts and the corresponding standard deviations in the ML, CC, and AP directions were -0.5 +/- 2.1 mm, 1.0 +/- 2.7 mm, and 0.7 +/- 1.1 mm, respectively. The random errors in the corresponding directions were 1.9 mm, 1.9 mm, and 2.2 mm. The PTV margins required in the absence of daily imaging were 3.7 mm to the right, 4.7 mm to the left, 4.4 mm inferior, 6.4 mm superior, 1.6 mm posterior, and 3.0 mm anterior. Conclusions: The current PTV margin of 3.0 mm is sufficient to ensure clinical target volume coverage for CSI tomotherapy patients treated with daily megavoltage computed tomography imaging. When pretreatment verification imaging is not used to lower the setup uncertainty, a larger PTV margin of up to 6.4 mm in the CC direction will be needed. (C) 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [1] Analysis of Setup Error for Craniospinal Irradiation Using Helical TomoTherapy
    Lee, J.
    Kim, E.
    Kim, N.
    Byun, H. K.
    Suh, C. O.
    Chung, Y.
    Yoon, H. I.
    MEDICAL PHYSICS, 2020, 47 (06) : E699 - E699
  • [2] DAILY SETUP UNCERTAINTY ANALYSIS FOR CRANIAL-SPINAL IRRADIATION USING HELICAL TOMOTHERAPY
    AlWassia, Rolina
    Bahig, Houda
    Poon, Emily
    Parker, William
    Freeman, Carolyn
    PEDIATRIC BLOOD & CANCER, 2011, 57 (05) : 865 - 865
  • [3] Analysis of Daily Setup Uncertainty For Cranial-spinal Irradiation Using Helical Tomotherapy
    Al Wassia, R.
    Bahig, H.
    Poon, E.
    Parker, W.
    Freeman, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S890 - S890
  • [4] CRANIOSPINAL IRRADIATION USING HELICAL TOMOTHERAPY: THE MCGILL EXPERIENCE
    Bahig, Houda
    Panet-Raymond, Valerie
    Freeman, Carolyn
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S76 - S77
  • [5] Pulmonary toxicity of craniospinal irradiation using helical tomotherapy
    Lee, Joongyo
    Kim, Euidam
    Kim, Nalee
    Suh, Chang-Ok
    Chung, Yoonsun
    Yoon, Hong In
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Pulmonary toxicity of craniospinal irradiation using helical tomotherapy
    Joongyo Lee
    Euidam Kim
    Nalee Kim
    Chang-Ok Suh
    Yoonsun Chung
    Hong In Yoon
    Scientific Reports, 12
  • [7] Clinical analysis of intracranial germinoma's craniospinal irradiation using helical tomotherapy
    Baolin Qu
    Lei Du
    Yurong Huang
    Wei Yu
    Boning Cai
    Shouping Xu
    Lin Ma
    Chinese Journal of Cancer Research, 2014, (03) : 247 - 254
  • [8] Clinical analysis of intracranial germinoma's craniospinal irradiation using helical tomotherapy
    Qu, Baolin
    Du, Lei
    Huang, Yurong
    Yu, Wei
    Cai, Boning
    Xu, Shouping
    Ma, Lin
    CHINESE JOURNAL OF CANCER RESEARCH, 2014, 26 (03) : 247 - 254
  • [9] Craniospinal Irradiation using Helical Tomotherapy for Paediatric Metastatic Medulloblastoma
    Loo, S. W.
    Horan, G.
    Lenane, M.
    Dean, J. C.
    Fairfoul, J.
    Cowen, M. A.
    Thomas, S. J.
    Burnet, N. G.
    Williams, M. V.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S44 - S44
  • [10] Helical Tomotherapy for Craniospinal Irradiation with Field Junctioning
    Jaradat, H.
    Xu, L.
    Lucas, G.
    Lee, T.
    MEDICAL PHYSICS, 2008, 35 (06)