MAGNETIC-RESONANCE ANGIOGRAPHY (MRA) OF THE ABDOMINAL VEINS

被引:0
作者
ARLART, IP
GUHL, L
FAUSER, L
EDELMAN, RR
KIM, D
LAUB, G
机构
[1] HARVARD UNIV,BETH ISRAEL HOSP,SCH MED,DEPT RADIOL,BOSTON,MA 02215
[2] SIEMENS MED TECH,ERLANGEN,GERMANY
来源
RADIOLOGE | 1991年 / 31卷 / 04期
关键词
MAGNETIC RESONANCE; VEINS; MR STUDIES; HEPATIC; ILIAC; PORTAL; RENAL; VENAE CAVAE; DIGITAL SUBTRACTION ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
On the basis of the time-of-flight effect in 18 normal volunteers and 119 patients with different diseases of the abdominal veins (inferior vena cava, portosplenic system, renal/hepatic/iliac veins) magnetic resonance (MR) angiograms were compared with the DSA, CT and US results. The MR technique included a series of 2D gradient-echo (Flash) images obtained which the patients held their breath and projection angiograms (PA) (MIP algorithm). PA of the inferior vena cava and renal veins had a sensitivity of 90% and a specificity of 88.8%. The results demonstrate that in all cases diseases of the large veins could be detected using all the MR information available. It is suggested that this method is so far not satisfactory in the evaluation of small vessels and slow intravascular flow conditions.
引用
收藏
页码:192 / 201
页数:10
相关论文
共 31 条
  • [1] ALFIDI RJ, 1987, AJR, V166, P231
  • [2] ANGLADE MC, 1988, DIAGN INTERV RADIOL, V1, P61
  • [3] ARLART IP, 1984, VASA-J VASCULAR DIS, V13, P127
  • [4] AQUEDUCTAL STENOSIS - EVALUATION WITH GRADIENT-ECHO RAPID MR IMAGING
    ATLAS, SW
    MARK, AS
    FRAM, EK
    [J]. RADIOLOGY, 1988, 169 (02) : 449 - 453
  • [5] AXEL L, 1986, Magnetic Resonance Imaging, V4, P199, DOI 10.1016/0730-725X(86)91059-3
  • [6] BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING
    AXEL, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1157 - 1166
  • [7] THE APPEARANCE OF RAPIDLY FLOWING BLOOD ON MAGNETIC-RESONANCE IMAGES
    BRADLEY, WG
    WALUCH, V
    LAI, KS
    FERNANDEZ, EJ
    SPALTER, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1167 - 1174
  • [8] BLOOD-FLOW - MAGNETIC-RESONANCE IMAGING
    BRADLEY, WG
    WALUCH, V
    [J]. RADIOLOGY, 1985, 154 (02) : 443 - 450
  • [9] MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE
    BRYANT, DJ
    PAYNE, JA
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 588 - 593
  • [10] Busch H P, 1985, Rontgenpraxis, V38, P7