THROTTLING WATER TUBES OF A GAS-TURBINE WASTE-HEAT BOILER WITH FORCED CIRCULATION

被引:0
作者
DOLEZAL, R
机构
来源
BRENNSTOFF-WARME-KRAFT | 1990年 / 42卷 / 12期
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The correct dimensioning of throttling at the evaporator of the once-through boiler in order to achieve equal water distribution at all pipes is important. The usual equations used for conventional boilers are not applicable for waste-heat boilers with a small temperature difference between flue gas and working medium, because the boundary conditions do not apply. A numerical determination, as described in this article, is unavoidable.
引用
收藏
页码:715 / 717
页数:3
相关论文
共 8 条
  • [1] BLUNK, 1968, BWK, V20, P63
  • [2] DOLEZAL R, 1990, BRENNST-WARME-KRAFT, V42, P49
  • [3] DOLEZAL R, 1987, LECTURES NOTES ENG
  • [4] GERICKE B, 1974, BWK, V26, P428
  • [5] HELLWIG U, 1988, BRENNST-WARME-KRAFT, V40, P277
  • [6] LEDINEGG M, 1952, DAMPFERZEUGUNG
  • [7] PROFOS P, 1959, ENERGIE, V11, P241
  • [8] SCHNACKENBERGER, 1937, WARME, V60, P481