TRACE ANALYSIS OF THE RADIONUCLIDES SR-90 AND SR-89 IN ENVIRONMENTAL-SAMPLES .3. DEVELOPMENT OF A FAST ANALYTICAL METHOD

被引:16
作者
ALFARO, J [1 ]
APFEL, T [1 ]
DIERCKS, H [1 ]
KNOCHEL, A [1 ]
SENGUPTA, R [1 ]
TODTER, K [1 ]
机构
[1] UNIV HAMBURG,INST ANORGAN & ANGEW CHEM,D-21049 HAMBURG,GERMANY
来源
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH | 1995年 / 34卷 / 02期
关键词
CHROMATOGRAPHY; ION CHROMATOGRAPHY; ONLINE DETECTORS; RADIONUCLIDES; STRONTIUM;
D O I
10.1002/anie.199501861
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Strontium‐90 is one of the most poisonous radionuclides. Its toxicity results from its long half‐life of 28.5 years and permanent deposition in the blood‐forming bone system. Strontium‐90 is formed in high yields during the nuclear fission of uranium‐235 and plutonium‐239. The classic analytical procedure for the determination of 90Sr, which relies on the β−‐radiation of the daughter nuclide yttrium‐90, necessitates the chemical removal of all accompanying nuclides. This method requires the Sr/Y ratio to be at equilibrium which takes about two to three weeks to achieve—far too long for the analysis of acute contaminations. Three communications deal with new procedures for ultra‐trace analysis using complex physical detection methods (resonance ionization and accelerator mass spectrometry) and high‐performance separation techniques (high‐performance ion chromatography, HPIC) are presented. In accordance with the strategies of the German Federal Ministry of the Environment, Nature Conservation, and Nuclear Safety, precision methods are described for the determination of the strontium‐90 content in aerosols. These techniques yield data for calculations of the spread of contaminants, which in turn yield results that can be verified in various samples with the aid of the novel fast detection method (HPIC with on‐line detectors). The three analytical procedures are set up in a modular manner and can therefore be utilized in variable combinations. They also indicate the high level of refinement achieved by modern ultra‐trace analyses. Copyright © 1995 by VCH Verlagsgesellschaft mbH, Germany
引用
收藏
页码:186 / 189
页数:4
相关论文
共 18 条
[1]  
ARSLAN F, 1995, ANGEW CHEM, V107, P205
[2]  
ARSLAN M, 1995, ANGEW CHEM INT EDIT, V34, P183
[3]   A NEW AMS BEAM LINE AT THE ERLANGEN TANDEM ACCELERATOR FACILITY [J].
BAUMGARTNER, M ;
EMMERLING, U ;
ERNST, W ;
FINCKH, E ;
FUCHS, G ;
GUMBMANN, F ;
HALLER, M ;
HOPFL, R ;
KARSCHNICK, R ;
KRETSCHMER, W ;
RAUSCHER, A ;
SCHLEICHER, M ;
SCHUSTER, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 50 (1-4) :286-290
[4]  
DANZER K, 1987, ANALYTIK
[5]  
DOERFEL K, 1990, STATISTIK ANALYTISCH
[6]  
FUNK W, 1992, QUALITATSSICHERUNG A
[7]  
KLOCKENKAMPER R, 1991, ANALYTIKER TASCHENBU, V10
[8]  
LANTSCH J, 1995, ANGEW CHEM, V107, P202
[9]   TRACE ANALYSIS OF THE RADIONUCLIDES SR-90 AND SR-89 IN ENVIRONMENTAL-SAMPLES .1. LASER MASS-SPECTROMETRY [J].
LANTZSCH, J ;
BUSHAW, BA ;
HERRMANN, G ;
KLUGE, HJ ;
MONZ, L ;
NIESS, S ;
OTTEN, EW ;
SCHWALBACH, R ;
SCHWARZ, M ;
STENNER, J ;
TRAUTMANN, N ;
WALTER, K ;
WENDT, K ;
ZIMMER, K .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1995, 34 (02) :181-183
[10]   FAST, LOW-LEVEL DETECTION OF SR-90 AND SR-89 IN ENVIRONMENTAL-SAMPLES BY COLLINEAR RESONANCE IONIZATION SPECTROSCOPY [J].
MONZ, L ;
HOHMANN, R ;
KLUGE, HJ ;
KUNZE, S ;
LANTZSCH, J ;
OTTEN, EW ;
PASSLER, G ;
SENNE, P ;
STENNER, J ;
STRATMANN, K ;
WENDT, K ;
ZIMMER, K ;
HERRMANN, G ;
TRAUTMANN, N ;
WALTER, K .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (14) :1655-1671