EFFECT OF NOISE ON COCHLEAR BLOOD-FLOW IN THE CONSCIOUS RABBIT

被引:63
作者
HULTCRANTZ, E [1 ]
机构
[1] UNIV UPPSALA,INST PHYSIOL & MED BIOPHYS,CTR BIOMED,S-75105 UPPSALA,SWEDEN
来源
ACTA PHYSIOLOGICA SCANDINAVICA | 1979年 / 106卷 / 01期
关键词
cerebral blood flow; Cochlear; microspheres; noise; sympathetics;
D O I
10.1111/j.1748-1716.1979.tb06366.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The cochlear blood flow was measured with the microsphere method in unanesthetized rabbits, prior to and during noise–exposure. Different sound pressure levels were used: 100 dB, 115 dB and 120 dB. Some of the animals had the cervical sympathetic trunk cut unilaterally. The effects of the delivered noise on the organ of Corti were studied in other rabbits with scanning electron microscopy. In spite of ultrastructural changes indicating damage of sensory cells after 115 dB and 120 dB exposure no changes of the total cochlear blood flow could be observed. After unilateral section of the cervical sympathetic trunk the cochlear blood flow was less on the intact side (25 %) already prior to noise exposure and the difference was not significantly affected by noise. Different sizes of microspheres were used: 8.2, 8.4, 8.7, 9.2 μAm. The 8.2 and 8.4 μ m–spheres seemed well fitted for measurements of cochlear blood flow but passed the cerebral capillaries to a high extent. Control experiments using both 8.2/8.4 μ m–spheres and 15 μ m–spheres were performed and the degree of passage in different tissues was estimated. © 1979 Scandinavian Physiological Society
引用
收藏
页码:29 / 37
页数:9
相关论文
共 25 条
[2]   TECHNIQUES FOR THE PRESERVATION OF 3-DIMENSIONAL STRUCTURE IN PREPARING SPECIMENS FOR THE ELECTRON MICROSCOPE [J].
ANDERSON, TF .
TRANSACTIONS OF THE NEW YORK ACADEMY OF SCIENCES, 1951, 13 (04) :130-134
[3]   COCHLEAR BLOOD-FLOW [J].
ANGELBORG, C ;
HULTCRANTZ, E ;
AGERUP, B .
ACTA OTO-LARYNGOLOGICA, 1977, 83 (1-2) :92-97
[4]  
ANGELBORG C, 1978 P BAR SOC
[5]  
BEAUSANGLINDER M, UNPUBLISHED
[6]  
BELL GJ, 1977, 1977 P BPS, P126
[7]   EFFECTS OF INDOMETHACIN ON REGIONAL BLOOD-FLOW IN CONSCIOUS RABBITS - MICROSPHERE STUDY [J].
BILL, A .
ACTA PHYSIOLOGICA SCANDINAVICA, 1979, 105 (04) :437-442
[8]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[9]  
FOLKOW B, 1971, CIRCULATION, P403
[10]   BRAIN BLOOD-FLOW IN CONSCIOUS AND ANESTHETIZED RAT [J].
GOLDMAN, H ;
SAPIRSTEIN, LA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1973, 224 (01) :122-126