Principles of CT: Radiation Dose and Image Quality

被引:294
作者
Goldman, Lee W. [1 ]
机构
[1] Hartford Hosp, Dept Radiat Therapy & Med Phys, 80 Seymour St, Hartford, CT 06102 USA
关键词
PET/CT; quality assurance; radiation safety; CT; CT technology; computed tomography;
D O I
10.2967/jnmt.106.037846
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article discusses CT radiation dose, the measurement of CT dose, and CT image quality. The most commonly used dose descriptor is CT dose index, which represents the dose to a location (e.g., depth) in a scanned volume from a complete series of slices. A weighted average of the CT dose index measured at the center and periphery of dose phantoms provides a convenient single-number estimate of patient dose for a procedure, and this value (or a related indicator that includes the scanned length) is often displayed on the operator's console. CT image quality, as in most imaging, is described in terms of contrast, spatial resolution, image noise, and artifacts. A strength of CT is its ability to visualize structures of low contrast in a subject, a task that is limited primarily by noise and is therefore closely associated with radiation dose: The higher the dose contributing to the image, the less apparent is image noise and the easier it is to perceive low-contrast structures. Spatial resolution is ultimately limited by sampling, but both image noise and resolution are strongly affected by the reconstruction filter. As a result, diagnostically acceptable image quality at acceptable doses of radiation requires appropriately designed clinical protocols, including appropriate kilovolt peaks, amperages, slice thicknesses, and reconstruction filters.
引用
收藏
页码:213 / 225
页数:13
相关论文
共 18 条
[1]   FILM DOSIMETRY SYSTEM FOR USE IN COMPUTED TOMOGRAPHY [J].
DIXON, RL ;
EKSTRAND, KE .
RADIOLOGY, 1978, 127 (01) :255-258
[2]   Principles of CT and CT Technology [J].
Goldman, Lee W. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (03) :115-128
[3]   PICTURE QUALITY OF COMPUTED TOMOGRAPHY [J].
HOUNSFIELD, GN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 127 (01) :3-9
[4]  
Hsieh J, 2000, SYLLABUS CATEGORICAL, P97
[5]  
Jucius RA, 1977, APPL OPTICAL INSTRUM, VVI
[6]  
Judy PF, 2000, 2000 SYLLABUS CATEGO, P117
[7]   Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements [J].
Kalender, WA ;
Wolf, H ;
Suess, C .
MEDICAL PHYSICS, 1999, 26 (11) :2248-2253
[8]   Calculation of effective dose [J].
McCollough, CH ;
Schueler, BA .
MEDICAL PHYSICS, 2000, 27 (05) :828-837
[9]  
McCollough CH, 2000, 2000 SYLLABUS CATEGO, P189
[10]   PATIENT DOSAGE IN COMPUTED TOMOGRAPHY [J].
MCCULLOUGH, EC ;
PAYNE, JT .
RADIOLOGY, 1978, 129 (02) :457-463