DIAMOND-LIKE CARBON-COATED FILMS FOR ENZYME ELECTRODES - CHARACTERIZATION OF BIOCOMPATIBILITY AND SUBSTRATE DIFFUSION LIMITING PROPERTIES

被引:30
作者
HIGSON, SPJ [1 ]
VADGAMA, PM [1 ]
机构
[1] UNIV MANCHESTER,HOPE HOSP,DEPT MED,CLIN BIOCHEM SECT,SALFORD M6 8HD,LANCS,ENGLAND
关键词
BIOSENSORS; DIAMOND LIKE CARBON COATED FILMS; ENZYME ELECTRODES;
D O I
10.1016/0003-2670(94)00380-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The biocompatibility and substrate diffusion limiting properties for a range of diamond like carbon (DLC) coated microporous polycarbonate and DLC coated dialysis (haemodialysis) membranes have been studied. This characterisation builds upon previous findings where DLC coated membranes imparted enhanced enzyme electrode performance. in this study electrode linear ranges have been extended from 10 mM glucose for a 0.01 mu m pore size membrane to 160 mM. These findings correlated with the duration of DLC deposition and associated reductions in permeability for glucose. Permeability coefficient ratios for both microporous and dialysis membranes were also found to be important with low glucose/O-2 permeability ratios imparting extensions in glucose linear response range. DLC coated membranes employed within enzyme electrodes have also been shown to exhibit enhanced haemocompatibility as determined by both sensitivity change and surface deposition of blood components examined by scanning electron microscopy. Correlations are made between the reduced losses in sensor response to biofouling/working electrode passivation processes, and extended linear ranges that DLC coated membranes may impart to enzyme electrode performance. Particular reference is made to the determination of glucose levels within whole blood.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 22 条
[1]  
ALBERY WJ, 1990, BIOSENS BIOELECTRON, V5, P379
[2]  
Angus J. C., 1987, P EUROPEAN MATERIALS, V17, P179
[3]  
Boyer P.D., 1963, ENZYMES
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]  
EVANS AC, 1991, MED DEVICE TECHN MAY, P26
[6]  
FRANKS J, 1989, J VAC SCI A, V71, P2307
[7]  
HALE PD, 1989, SYNTHETIC MET, V28, pC853
[8]   AMPEROMETRIC ENZYME ELECTRODE BIOFOULING AND PASSIVATION IN BLOOD - CHARACTERIZATION OF WORKING ELECTRODE POLARIZATION AND INNER MEMBRANE EFFECTS [J].
HIGSON, SPJ ;
DESAI, MA ;
GHOSH, S ;
CHRISTIE, I ;
VADGAMA, P .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (15) :2847-2851
[9]   DIAMOND-LIKE CARBON COATED MICROPOROUS POLYCARBONATE AS A COMPOSITE BARRIER FOR A GLUCOSE ENZYME ELECTRODE [J].
HIGSON, SPJ ;
VADGAMA, PM .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :125-133
[10]  
HOUGIE C, 1984, HUMAN BLOOD COAGULAT